Purpose: To evaluate neonatal and maternal outcomes associated with detachment of non-metal vacuum cup during delivery and to identify risk factors for these detachments.

Methods: This retrospective cohort study included women with singleton pregnancy, who underwent vacuum-assisted vaginal delivery with a non-metal vacuum cup in a single academic institution, January 2014-August 2019. Failed vacuum deliveries were excluded. Primary outcomes were defined as subgaleal hematoma (SGH) and cord blood pH < 7.15. Secondary outcome included other neonatal complications and adverse maternal outcomes. Outcomes were compared between vacuum-assisted deliveries with and without cup detachment during the procedure.

Results: A total of 3246 women had successful VAD and met the inclusion criteria. During the procedure, the cup detached at least once in 665 (20.5%) deliveries and did not detach in 2581 (79.5%). The cup detachment group experienced higher rates of SGH (8.9% vs. 3.5%, p = 0.001) and cord blood pH < 7.15 (9.8% vs. 7.1%, p = 0.03). There were also more neonatal intensive care unit admissions (NICU) (4.4% vs. 2.7%, p = 0.03) and more fetuses with occiput posterior position (70.8% vs. 79.4%, p = 0.001), the vacuum duration was slightly longer (6 ± 3.7 vs. 5 ± 2.9 min) and more neonates had birth weights > 3700 g (14.1% vs, 10.3%, p = 0.006). Interestingly, there were more males in that group (60.6 vs. 54.6, p = 0.005). All these factors remained significant after controlling for potential confounders.

Conclusions: Vacuum cup detachment has several predictive characteristics and is associated with adverse neonatal outcomes that should be incorporated into decisions made during the procedure.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00404-021-06155-yDOI Listing

Publication Analysis

Top Keywords

detachment non-metal
8
retrospective cohort
8
cohort study
8
non-metal vacuum
8
vacuum cup
8
adverse outcomes
4
outcomes vacuum-assisted
4
vacuum-assisted delivery
4
delivery detachment
4
non-metal cup
4

Similar Publications

Purpose: To evaluate neonatal and maternal outcomes associated with detachment of non-metal vacuum cup during delivery and to identify risk factors for these detachments.

Methods: This retrospective cohort study included women with singleton pregnancy, who underwent vacuum-assisted vaginal delivery with a non-metal vacuum cup in a single academic institution, January 2014-August 2019. Failed vacuum deliveries were excluded.

View Article and Find Full Text PDF

[Combining diagnosis of IOFB and complications with multiple image-related methods].

Zhonghua Yan Ke Za Zhi

September 2003

Department of Ophthalmology, First Teaching Hospital, Zhengzhou University, Zhengzhou, 450052, China.

Objective: To evaluate the roles of diagnosing intraocular foreign body (IOFB) and their complications with CT, B-scan, X-ray film, MRI and UBM.

Methods: Retrospective study of 103 clinic inpatient cases.

Results: CT showing rate was 100% (103/103), CT scan could identify positions of high density IOFB, and define metal or non-metal.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!