Neutron-induced mass shift of tin isotopes recognized using inductively coupled plasma mass spectrometry as an isotopic fingerprint on neutron reactions.

Appl Radiat Isot

Experimental Nuclear Physics Department, Nuclear Research Center, Egyptian Atomic Energy Authority, Cairo, 13759, Egypt. Electronic address:

Published: October 2021

The phenomenon of isotope shift in response to neutron irradiation was investigated. The high fission-neutron fluence of 1.44×10 cm from the second Egyptian research reactor (ETRR-2) was used to induce a mass shift in a metallic tin sample. A triple-quadrupole inductively coupled plasma mass spectrometry system was used to analyze the isotope abundances in the mass range from A=111 to A=125. The problem of mass bias due to kinetic fractionation on use of the inductively coupled plasma mass spectrometry system was treated by our calibrating the mass bias with a standard reference tin solution and building a response function. The response function was used to obtain absolute abundances in each mass range instead of isotope ratios. The results show that the mass shifts in the irradiated sample are dependent on the cross section of the neutron capture reaction in the tin isotopes.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.apradiso.2021.109872DOI Listing

Publication Analysis

Top Keywords

inductively coupled
12
coupled plasma
12
plasma mass
12
mass spectrometry
12
mass
9
mass shift
8
tin isotopes
8
spectrometry system
8
abundances mass
8
mass range
8

Similar Publications

Intranasal iron administration induces iron deposition, immunoactivation, and cell-specific vulnerability in the olfactory bulb of C57BL/6 mice.

Zool Res

January 2025

School of Basic Medicine, Institute of Brain Science and Disease, Shandong Provincial Key Laboratory of Pathogenesis and Prevention of Brain Diseases, Qingdao University, Qingdao, Shandong, 266071, China. E-mail:

Iron is the most abundant transition metal in the brain and is essential for brain development and neuronal function; however, its abnormal accumulation is also implicated in various neurological disorders. The olfactory bulb (OB), an early target in neurodegenerative diseases, acts as a gateway for environmental toxins and contains diverse neuronal populations with distinct roles. This study explored the cell-specific vulnerability to iron in the OB using a mouse model of intranasal administration of ferric ammonium citrate (FAC).

View Article and Find Full Text PDF

Introduction: Infertility has significant implications on health. It affects physical, emotional, and social wellbeing. In Morocco, about 12% of couples or live with infertility.

View Article and Find Full Text PDF

This study sought to validate the external calibration curve (CAL) method for iodine analysis in 26 selected foods and then to compare the test result with the isotope dilution mass spectrometry (IDMS). Iodine was extracted by tetramethylammonium hydroxide (TMAH) and determined by ICP-MS using CAL and IDMS methods. The results showed that iodine determination using the IDMS method had higher precision than the CAL method (LOD of the method were 0.

View Article and Find Full Text PDF

Hydroxyapatite, renowned for its biocompatibility and osteoconductive properties, plays a fundamental role in bone regeneration owing to its resemblance to natural bone mineral, thus offering considerable potential for advancing tissue engineering strategies. In this article, the innovative integration of silicon ions into biogenic (bovine-derived) hydroxyapatite (SiBHA) via a tailored sol-gel process is reported. The resultant SiBHA scaffolds exhibited an interconnected microporous structure with a total porosity of 70% and pore dimensions ranging from 120 to 650 µm.

View Article and Find Full Text PDF

The long-term stability of Pt-based catalysts is critical to the reliability of proton exchange membrane fuel cells (PEMFCs), and receives constant attention. However, the current knowledge of Pt oxidation is restricted to unrealistic PEMFC cathode environment or operation, which questions its practical relevance. Herein, Pt oxidation is investigated directly in a PEMFC with stroboscopic operando high energy X-ray scattering.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!