A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Support vector machine and deep-learning object detection for localisation of hard exudates. | LitMetric

Support vector machine and deep-learning object detection for localisation of hard exudates.

Sci Rep

Faculty of Electrical Engineering and Information Technology, Slovak University of Technology, Ilkovičova 3, 812 19, Bratislava, Slovakia.

Published: August 2021

Hard exudates are one of the main clinical findings in the retinal images of patients with diabetic retinopathy. Detecting them early significantly impacts the treatment of underlying diseases; therefore, there is a need for automated systems with high reliability. We propose a novel method for identifying and localising hard exudates in retinal images. To achieve fast image pre-scanning, a support vector machine (SVM) classifier was combined with a faster region-based convolutional neural network (faster R-CNN) object detector for the localisation of exudates. Rapid pre-scanning filtered out exudate-free samples using a feature vector extracted from the pre-trained ResNet-50 network. Subsequently, the remaining samples were processed using a faster R-CNN detector for detailed analysis. When evaluating all the exudates as individual objects, the SVM classifier reduced the false positive rate by 29.7% and marginally increased the false negative rate by 16.2%. When evaluating all the images, we recorded a 50% reduction in the false positive rate, without any decrease in the number of false negatives. The interim results suggested that pre-scanning the samples using the SVM prior to implementing the deep-network object detector could simultaneously improve and speed up the current hard exudates detection method, especially when there is paucity of training data.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8346563PMC
http://dx.doi.org/10.1038/s41598-021-95519-0DOI Listing

Publication Analysis

Top Keywords

hard exudates
16
support vector
8
vector machine
8
retinal images
8
svm classifier
8
faster r-cnn
8
object detector
8
false positive
8
positive rate
8
exudates
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!