[The Auxiliary Diagnostic Value of Serum Adenosine Deaminase in Acute Leukemia at Clinical Test].

Zhongguo Shi Yan Xue Ye Xue Za Zhi

Department of Clinical Laboratory Examination, Zhejiang Hospital, Hangzhou 310000, Zhejiang Province, China

Published: August 2021

AI Article Synopsis

Article Abstract

Objective: To investigate the auxiliary diagnostic value of serum adenosine deaminase (ADA) in acute leukemia (AL) at clinical test.

Methods: 123 AL patients hospitalized in Zhejiang hospital from November 2018 to March 2020 were enrolled as the observation group, and 98 healthy people in the same period were randomly enrolled as the control group. AL patients were divided into two groups: 77 acute myeloid leukemia (AML) patients for AML group and 46 acute lymphoblastic leukemia (ALL) patients for ALL group. The levels of adenosine deaminase (ADA), alanine aminotransferase (ALT), aspartate aminotransferase (AST), glutamyl transpeptidase (GGT), lactate dehydrogenase (LDH) and homocysteine (Hcy) in serum of the patients were detected, and the correlation of ADA with these items was analyzed. Receiver operating characteristic curve (ROC) was used to analyze the clinical diagnostic value of ADA, Yoden index was used to confirm the best cut-off point.

Results: The serum ADA level in AL patients was significant higher than that in control group (P < 0.05). The results of Pearson correlation analysis showed that there was a significant positive correlation of ADA with Hcy, ALT, AST, GGT, LDH in AML group (r = 0.47, r = 0.28, r = 0.37, r = 0.22, r = 0.55); and also there was a significant positive correlation of ADA with GGT in ALL group (r = 0.54). In AML group, the maximum area under ROC curve was 0.761 (P = 0.00), 95% confidence interval was 0.682-0.841, sensitivity was 54.50%, specificity was 98.90%, and the best cut-off point was 17.1 U/L. In ALL group, the maximum area under ROC curve was 0.785, 95% confidence interval was 0.694-0.877, sensitivity was 65.90%, specificity was 84.00%, and the best cut-off point was 13.45 U/L.

Conclusion: The detection of ADA in serum can be used as an auxiliary examination in patients with AL, which can provide a certain value for the diagnosis of the disease.

Download full-text PDF

Source
http://dx.doi.org/10.19746/j.cnki.issn.1009-2137.2021.04.015DOI Listing

Publication Analysis

Top Keywords

adenosine deaminase
12
aml group
12
correlation ada
12
best cut-off
12
group
9
auxiliary diagnostic
8
diagnostic serum
8
serum adenosine
8
acute leukemia
8
leukemia clinical
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!