Background: Intravenous misplacement of a nephrostomy tube is a rare complication of percutaneous nephrolithotomy (PCNL) or percutaneous nephrostomy. The mechanism of misplacement of a nephrostomy tube into the vascular system is seldom investigated. One type of the possible mechanism is that the puncture needle penetrates a major intrarenal tributary of the renal vein and enters the collecting system. However, the guidewire is located outside the collecting system near the large branches of renal vein or perforates into the renal vein. The dilation is performed and causes a large torn injury. Subsequently, the nephrostomy tube is placed inside the vessel when radiological monitoring is not used. However, there is no imaging evidence and the scene of procedure is not demonstrated. This paper reports two cases of visualization of the renal vein filled with contrast agent during PCNL. The findings may be good evidence to support the step of renal vein injury in patients with intravenous nephrostomy tube misplacement.
Case Presentation: We presented two cases with visualization of the renal vein filled with contrast agent during PCNL. In the process of injecting the contrast agent through the puncture needle, we could see the renal vein. Moreover, it was identified that the puncture needle tip was not on the optimal position. The position of puncture needle tip lay outside the collecting system, which was close to the calyceal infundibulum and branches of renal vein.
Conclusions: Visualization of the renal vein filled with contrast agent may be good evidence to verify the renal vein injury in patients with intravenous nephrostomy tube misplacement during PCNL or percutaneous nephrostomy. The suboptimal location of the puncture needle tip and visualization of the renal vein filled with contrast agent indicate the renal vein injury. One type of mechanism of intravenous nephrostomy tube misplacement is as following. Firstly, the guidewire stays outside the collecting system. Subsequently, dilatation directed by the guidewire results in the injury of the vein. Then, the nephrostomy tube migrates into the venous system due to prompt tube inserting and the direction of the sheath and/or the guidewire to the injured vein.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8348810 | PMC |
http://dx.doi.org/10.1186/s12894-021-00868-7 | DOI Listing |
Background: When inserting central venous catheters, inadvertent injury of major vessels is a rare yet critical complication. Direct surgery is sometimes overly invasive. This report describes a subclavian artery injury caused by inadvertent cannulation of a dialysis catheter, successfully treated with a covered stent.
View Article and Find Full Text PDFRen Fail
December 2025
Department of Nephrology, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, China.
Objectives: Vascular access thrombosis (VAT) is a common complication in patients with end-stage renal disease (ESRD), significantly impacting hemodialysis efficacy and patient survival. Currently, temporary dialysis access is typically established deep vein catheterization (VC), however, this method is highly invasive and associated with risks of infection and other complications. This study aims to explore the feasibility of using direct anastomosis indwelling needle puncture (DAINP) for temporary dialysis access.
View Article and Find Full Text PDFTransplant Proc
January 2025
Servicio de Urología, Hospital Universitario Cruces, Barakaldo, Bizkaia, Spain.
Introduction: The length of the right renal vein is a crucial vascular factor in kidney transplantation. Its shorter length compared to the left renal vein complicates venous anastomosis. The aim of this article is to review the literature on this topic and provide data from our experience.
View Article and Find Full Text PDFCardiovasc Intervent Radiol
January 2025
Department of Radiology, Southampton University Hospitals, Southampton, UK.
Objective: To assess tumour factors that reduce primary technical efficacy (PTE) from CT-guided renal cryoablation.
Methods: Patients were taken from the EuRECA registry between December 2014 and November 2020. To focus on tumour factors rather than individual technique, this study was limited to cases using CT and excluded procedures using cone beam, US, MRI, or laparoscopy.
Ultrasound J
January 2025
Department of Internal Medicine, University of Colorado Hospital, 12631 E 17thAvenue, Aurora, CO, 80045, USA.
Background: Understanding venous congestion is critical to the management of many illnesses, but assessing volume status can be challenging. The current gold standard for volume status assessment of right heart catheterization (RHC) is invasive, costly, and often unavailable. Venous Excess Ultrasound Score (VExUS) is a novel ultrasound protocol for to assessment of venous congestion using the inferior vena cava, hepatic, portal and renal veins.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!