A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 143

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 994
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3134
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Custom 3D-Printed Cutting Guides for Femoral Osteotomy in Rotational Malalignment Due to Diaphyseal Fractures: Surgical Technique and Case Series. | LitMetric

AI Article Synopsis

  • * A common issue after this treatment is rotational malalignment, which can lead to functional issues due to abnormal femoral rotation.
  • * Researchers developed a 3D printing method for personalized cutting guides to correct femoral malrotation, resulting in successful surgeries that normalized the femoral anteversion angle in patients.

Article Abstract

Femoral shaft fractures are one of the most common injuries in trauma patients. The gold standard treatment consists of closed reduction and intramedullary nailing, providing a high fracture healing rate and allowing early mobilization. However, rotational malalignment is a well-known complication following this procedure, and excessive femoral anteversion or femoral retroversion can trigger functional complaints. In order to achieve the ideal degree of femoral rotation, a 3D planning and printing cutting guides procedure was developed to correct femoral malrotation. A patient series with malalignment after a femoral diaphyseal fracture was operated on with the customized guides and evaluated in this study. Computed tomography scans were performed to accurately determine the number of degrees of malrotation, allowing the design of specific and personalized surgical guides to correct these accurately. Once designed, they were produced by 3D printing. After surgery with the customized guides to correct femoral malrotation, all patients presented a normalized anteversion angle of the femur (average -10.3°, range from -5° to -15°), according to their contralateral limb. These data suggest that the use of customized cutting guides for femoral osteotomy is a safe and reproducible surgical technique that offers precise results when correcting femoral malrotation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8348349PMC
http://dx.doi.org/10.3390/jcm10153366DOI Listing

Publication Analysis

Top Keywords

cutting guides
12
femoral malrotation
12
femoral
10
guides femoral
8
femoral osteotomy
8
rotational malalignment
8
surgical technique
8
correct femoral
8
customized guides
8
guides correct
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!

A PHP Error was encountered

Severity: Notice

Message: fwrite(): Write of 34 bytes failed with errno=28 No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 272

Backtrace:

A PHP Error was encountered

Severity: Warning

Message: session_write_close(): Failed to write session data using user defined save handler. (session.save_path: /var/lib/php/sessions)

Filename: Unknown

Line Number: 0

Backtrace: