: To evaluate interobserver and intertest agreement between optical coherence tomography (OCT) and retinography in the detection of glaucoma through a telemedicine program. : A stratified sample of 4113 individuals was randomly selected, and those who accepted underwent examination including visual acuity, intraocular pressure (IOP), non-mydriatic retinography, and imaging using a portable OCT device. Participants' data and images were uploaded and assessed by 16 ophthalmologists on a deferred basis. Two independent evaluations were performed for all participants. Agreement between methods was assessed using the kappa coefficient and the prevalence-adjusted bias-adjusted kappa (PABAK). We analyzed potential factors possibly influencing the level of agreement. : The final sample comprised 1006 participants. Of all suspected glaucoma cases ( = 201), 20.4% were identified in retinographs only, 11.9% in OCT images only, 46.3% in both, and 21.4% were diagnosed based on other data. Overall interobserver agreement outcomes were moderate to good with a kappa coefficient of 0.37 and a PABAK index of 0.58. Higher values were obtained by experienced evaluators (kappa = 0.61; PABAK = 0.82). Kappa and PABAK values between OCT and photographs were 0.52 and 0.82 for the first evaluation. : In a telemedicine screening setting, interobserver agreement on diagnosis was moderate but improved with greater evaluator expertise.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8347319PMC
http://dx.doi.org/10.3390/jcm10153337DOI Listing

Publication Analysis

Top Keywords

interobserver intertest
8
intertest agreement
8
optical coherence
8
coherence tomography
8
kappa coefficient
8
kappa pabak
8
interobserver agreement
8
agreement
6
kappa
5
interobserver
4

Similar Publications

Background: Pancreatic cancer is an aggressive malignancy and a leading cause of cancer death worldwide; its lethality is partly linked to the difficulty of early diagnosis. Modern devices for endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) were recently developed to improve targeting and sampling of small lesions, but innovative technologies for microscopic assessment are still lacking. Ex vivo fluorescence confocal laser microscopy (FCM) is a new digital tool for real-time microscopic assessment of fresh unfixed biological specimens, avoiding conventional histological slide preparation and potentially being highly appealing for EUS-FNB specimens.

View Article and Find Full Text PDF

Objectives: The radiological measurement of the Böhler angle (BA) and the critical angle of Gissane (CAG) is used not only to diagnose and corroborate the suspicion of the presence of calcaneal fractures but also to assess the prognosis of different injury patterns and to evaluate the operative reduction of calcaneal fractures. Notwithstanding, many previous studies indicated the poor intra- and interobserver reproducibility of both angles. In this retrospective study, we present the subtalar calcaneal angle (SCA) as an additional diagnostic tool -to BA and CAG-which can be applied on pre- and postoperative radiographs to assess calcaneal fractures involving the posterior facet.

View Article and Find Full Text PDF

Computed tomography angiography for quantification of cerebral vasospasm following aneurysmal subarachnoid hemorrhage.

Diagn Interv Imaging

March 2022

Department of Neuroradiology, Hôpital Lariboisière, Assistance Publique-Hôpitaux de Paris, Paris 75010, France; Faculté de Médecine, Université de Paris, Paris 75010, France. Electronic address:

Purpose: The purpose of this study was to assess the accuracy of computed tomography angiography (CTA) for quantification of cerebral vasospasm following aneurysmal subarachnoid hemorrhage in proximal and middle segments of intracranial arteries.

Materials And Methods: Twenty consecutive patients (7 men, 13 women; mean age, 47 ± 7 [SD] years; age range: 27-78 years) with aneurysmal subarachnoid hemorrhage who underwent CTA and digital subtracted angiography (DSA) with a 6-hour window at baseline and during vasospasm period were included. Twelve artery segments were analyzed in each patient.

View Article and Find Full Text PDF

: To evaluate interobserver and intertest agreement between optical coherence tomography (OCT) and retinography in the detection of glaucoma through a telemedicine program. : A stratified sample of 4113 individuals was randomly selected, and those who accepted underwent examination including visual acuity, intraocular pressure (IOP), non-mydriatic retinography, and imaging using a portable OCT device. Participants' data and images were uploaded and assessed by 16 ophthalmologists on a deferred basis.

View Article and Find Full Text PDF

Background: Proximal full-thickness free hamstring tendon injury (ie, tendon avulsion or rupture) is a severe injury. Treatment decision making relies on clinical factors and magnetic resonance imaging (MRI) variables; it specifically relies on which tendons are injured as well as the extent of tendon retraction. According to a worldwide evaluation of current practice, discontinuity of both proximal tendons and retraction of >2 cm are used as surgical indications.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!