ZIF-8@GMP-Tb nanocomplex for ratiometric fluorescent detection of alkaline phosphatase activity.

Spectrochim Acta A Mol Biomol Spectrosc

Key Laboratory of Eco-Environments in Three Gorges Reservoir Region (Ministry of Education), School of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, People's Republic of China. Electronic address:

Published: January 2022

Luminescent metal-organic frameworks (LMOFs) and their functional materials with unique characteristics can provide the basis for the construction of new analytical techniques, which can meet the continuous demand for various fields. In this work, guanosine monophosphate (GMP), terbium ion (Tb) and zeolitic imidazolate framework-8 (ZIF-8) are self-assembled to form a ZIF-8@GMP-Tb nanocomplex, which can be utilized as a ratiometric fluorescent probe to monitor alkaline phosphatase (ALP) activity. Specifically, with adding ALP, the fluorescence intensity at 547 nm (one of the characteristic emission peaks of Tb) obviously decreased. Meanwhile, the conjugated structure of GMP increased the fluorescence of ZIF-8 (located at 330 nm). The possible mechanism was proposed through the characterization of the materials. Based on the variation of the emission peaks at 330 and 547 nm, the ratiometric fluorescent sensor of ALP has a linear range of 0.25-20 U/L. Moreover, applying this sensing system to the detection of ALP in the human serum sample and ALP inhibitor investigation possesses satisfactory results. This work provides a new perspective for the utilization of ZIF-8 and lanthanide ions in manufacturing simple and sensitive sensors.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.saa.2021.120230DOI Listing

Publication Analysis

Top Keywords

ratiometric fluorescent
12
zif-8@gmp-tb nanocomplex
8
alkaline phosphatase
8
emission peaks
8
alp
5
nanocomplex ratiometric
4
fluorescent detection
4
detection alkaline
4
phosphatase activity
4
activity luminescent
4

Similar Publications

Background: Ochratoxin A (OTA) is toxic secondary metabolites produced by fungi and can pose a serious threat to food safety and human health. Due to the high stability and toxicity, OTA contamination in agricultural products is of great concern. Therefore, the development of a highly sensitive and reliable OTA detection method is crucial to ensure food safety.

View Article and Find Full Text PDF

A Spectroscopic Methodology to Early Detection of Urinary Tract Infections.

Sensors (Basel)

January 2025

Centro de Química Estrutural, Institute of Molecular Sciences, Departamento de Química e Bioquímica, Faculdade de Ciências, Universidade de Lisboa, Campo Grande, 1749-016 Lisboa, Portugal.

Healthcare-associated infections (HAI) are a critical public health problem, with 30 to 40% of infections related to the urinary tract system. These urinary tract infections (UTIs) are considered one of the most common microbial infections in hospital settings and everyday community contexts, where approximately 80% are highly correlated with urinary catheter insertion, i.e.

View Article and Find Full Text PDF

Ratiometric lanthanide coordination polymers (Ln-CPs) are advanced materials that combine the unique optical properties of lanthanide ions (e.g., Eu, Tb, Ce) with the structural flexibility and tunability of coordination polymers.

View Article and Find Full Text PDF

Environmental changes, such as applied medication, nutrient depletion, and accumulation of metabolic residues, affect cell culture activity. The combination of these factors reflects on the local temperature distribution and local oxygen concentration towards the cell culture scaffold. However, determining the temporal variation of local temperature, independent of local oxygen concentration changes in biological specimens, remains a significant technological challenge.

View Article and Find Full Text PDF

A fluorescent probe (NBC), constructed by benzothiazole-coumarin and naphthalimide derivatives, was developed for the detection of SO derivatives using the FRET (Förster Resonance Energy Transfer) strategy. NBC presented large Stokes shift (180 nm), fast response (2 min), high sensitivity (LOD: 45 nM) and an excellent linear relationship in response to SO derivatives. Moreover, NBC has been successfully applied to detect SO derivatives in food samples and living cells.

View Article and Find Full Text PDF