Objective: T1-weighted MRI images are commonly used for volumetric assessment of brain structures. Magnetization prepared 2 rapid gradient echo (MP2RAGE) sequence offers superior gray (GM) and white matter (WM) contrast. This study aimed to quantitatively assess the agreement of whole brain tissue and deep GM (DGM) volumes obtained from MP2RAGE compared to the widely used MP-RAGE sequence.

Methods: Twenty-nine healthy participants were included in this study. All subjects underwent a 3T MRI scan acquiring high-resolution 3D MP-RAGE and MP2RAGE images. Twelve participants were re-scanned after one year. The whole brain, as well as DGM segmentation, was performed using CAT12, volBrain, and FSL-FAST automatic segmentation tools based on the acquired images. Finally, contrast-to-noise ratio between WM and GM (CNRWG), the agreement between the obtained tissue volumes, as well as scan-rescan variability of both sequences were explored.

Results: Significantly higher CNRWG was detected in MP2RAGE vs. MP-RAGE (Mean ± SD = 0.97 ± 0.04 vs. 0.8 ± 0.1 respectively; p<0.0001). Significantly higher total brain GM, and lower cerebrospinal fluid‏ volumes were obtained from MP2RAGE vs. MP-RAGE based on all segmentation methods (p<0.05 in all cases). Whole-brain voxel-wise comparisons revealed higher GM tissue probability in the thalamus, putamen, caudate, lingual gyrus, and precentral gyrus based on MP2RAGE compared with MP-RAGE. Moreover, significantly higher WM probability was observed in the cerebellum, corpus callosum, and frontal-and-temporal regions in MP2RAGE vs. MP-RAGE. Finally, MP2RAGE showed a higher mean percentage of change in total brain GM compared to MP-RAGE. On the other hand, MP-RAGE demonstrated a higher overtime percentage of change in WM and DGM volumes compared to MP2RAGE.

Conclusions: Due to its higher CNR, MP2RAGE resulted in reproducible brain tissue segmentation, and thus is a recommended method for volumetric imaging biomarkers for the monitoring of neurological diseases.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8345829PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0254597PLOS

Publication Analysis

Top Keywords

mp2rage
5
brain
4
brain deep
4
deep gray
4
gray matter
4
matter structure
4
structure segmentation
4
segmentation quantitative
4
quantitative comparison
4
comparison mprage
4

Similar Publications

Log subtracted inversion recovery.

Magn Reson Imaging

January 2025

Mātai Medical Research Institute, Tairāwhiti, Gisborne, New Zealand; Department of Radiology, University of California San Diego, San Diego, CA, USA. Electronic address:

Magnetic resonance imaging (MRI) techniques have recently been developed for obtaining high T contrast images using inversion recovery (IR) images at two inversion times (TIs) rather than a single TI. They use simple mathematical operations - multiplication, addition, subtraction, division - to create images not attainable by conventional IR. The present study describes a novel two-point IR technique formed by the subtraction of log images.

View Article and Find Full Text PDF

Background And Purpose: Degenerative cervical myelopathy (DCM) is the most common cause of spinal cord (SC) dysfunction. In routine clinical practice, SC changes are well depicted using conventional MRI, especially T2-weighted imaging. However, this modality usually fails to provide satisfactory clinico-radiological correlations.

View Article and Find Full Text PDF

Comparison and calibration of MP2RAGE quantitative T1 values to multi-TI inversion recovery T1 values.

Magn Reson Imaging

January 2025

Department of Electrical and Computer Engineering, Vanderbilt University, Nashville, TN, United States; Department of Computer Science, Vanderbilt University, Nashville, TN, United States; Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, United States; Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, TN, United States; Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, United States.

While typical qualitative T1-weighted magnetic resonance images reflect scanner and protocol differences, quantitative T1 mapping aims to measure T1 independent of these effects. Changes in T1 in the brain reflect structural changes in brain tissue. Magnetization-prepared two rapid acquisition gradient echo (MP2RAGE) is an acquisition protocol that allows for efficient T1 mapping with a much lower scan time per slab compared to multi-TI inversion recovery (IR) protocols.

View Article and Find Full Text PDF

Improved MR Detection of Optic Nerve Demyelination With MP2RAGE-FLAWS Compared With T2-Weighted Fat-Saturated Sequences.

Invest Radiol

November 2024

From the Department of Neuroradiology, AP-HP, Henri Mondor University Hospital, Créteil, France (R.A., T.E., I.M., B.B.); University Paris Est Créteil, INSERM, IMRB, Créteil, France (N.O.); Department of Public Health, AP-HP, Henri Mondor University Hospital, Créteil, France (N.O.); EA 4391, Université Paris Est Créteil, Créteil, France (A.C., B.B.); Department of Neurology, AP-HP, Henri Mondor University Hospital, Créteil, France (A.C.); Department of Neuroradiology, A. Rothschild Foundation Hospital, Paris, France (A.L.); Paris Cité University, Paris, France (A.L.); Advanced Clinical Imaging Technology, Siemens Healthineers International AG, Lausanne, Switzerland (T.K.); Department of Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland (T.K.); Signal Processing Laboratory (LTS 5), École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland (T.K.); and Siemens Healthcare SAS, Courbevoie, France (A.M.).

Objectives: Nonenhanced T1-w sequences such as magnetization-prepared 2 rapid acquisition gradient echo (MP2RAGE) and derived fluid and white matter suppression (FLAWS) have demonstrated high performance for detecting brain parenchymal and cervical spine demyelinating lesions in multiple sclerosis. However, their potential for identifying optic nerve (ON) demyelination remains unexplored. The aim of this study was to evaluate the performance of compressed sensing-accelerated (CS) MP2RAGE-FLAWS imaging for detection of ON demyelination lesions compared with T2-w fat-saturated (FS) TSE imaging in a clinical setting.

View Article and Find Full Text PDF

Purpose: Regarding in vivo, robust longitudinal relaxation rate (R) mapping, the goal of the present paper is two-fold. First, to verify that non-bijective mapping in magnetization-prepared 2 rapid gradient echo (MP2RAGE) imaging can be resolved through a two-dimensional look-up table approach. Second, that the expanded parameter space from this can be used to improve -inhomogeneity tolerance without other prerequisites.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!