The Relevance Of The Study: Is dictated by the insufficient strength of the bases of removable plate prostheses made of acrylic plastic masses. The literature data confirm the high prevalence of strips of removable plate prostheses made of acrylic plastics, regardless of the complexity of the clinical situation, but in great dependence on the time of use of prostheses. The search for new approaches to reduce the risks of structural failures, regardless of the operating time, led to the emergence of a metal mesh and a composite frame.

The Purpose Of The Work: Is a comparative analysis of the resistance of structures to moisture and heat, in accordance with GOST R 57695-2017, aimed at modeling the aging of samples from acrylic polymers reinforced with a metal mesh and a composite frame based on fiberglass.

Materials And Methods: The whole experiment was carried out in accordance with GOST R 57695-2017 and was aimed at modeling the aging of three types of samples of acrylic polymers and combinations: «acrylic polymer-metal mesh», «acrylic polymer-composite frame» of size 20×18×1, 8 mm for studying microstructure and morphology. The obtained profiles of samples with a simulated aging effect were evaluated using an Axiovert 40MT optical microscope (Carl Zeiss), with an increase of ×200, ×500.

Results: Analysis of the microstructure data showed that profiles of 3 types of samples before exposure to aging factors have a homogeneous structure with a rough surface. With an increase of ×500 in four samples with a metal mesh, both before and after exposure to moisture and heat, the presence of voids between the base material and the metal reinforcing component is noted. In samples reinforced with composite material, its pronounced integration with acrylic plastic is preserved, which is due to the presence of a chemical bond. During the experiment, it was found that the conditions modeled according to GOST R 57695-2017 do not significantly affect the structure of the samples, and the morphology analysis revealed a close fit between the components of the materials in the combined samples and the absence of changes at the interface.

Conclusions: The proposed option of reinforcing the base of a removable laminar denture, due to the introduction of a skeleton made of composite material based on fiberglass, is optimal for increasing the effectiveness of orthopedic treatment.

Download full-text PDF

Source
http://dx.doi.org/10.17116/stomat202110004177DOI Listing

Publication Analysis

Top Keywords

metal mesh
12
gost 57695-2017
12
samples
9
combined samples
8
removable plate
8
plate prostheses
8
prostheses acrylic
8
acrylic plastic
8
mesh composite
8
moisture heat
8

Similar Publications

Metallic biomaterials are extensively used in orthopedics and dentistry, either as implants or coatings. In both cases, metal ions come into contact with surrounding tissues causing a particular cell response. Here, we present a biofabricated tissue model, consisting of a hydrogel reinforced with a melt electrowritten mesh, to study the effects of bound and released metal ions on surrounding cells embedded in a hydrogel matrix.

View Article and Find Full Text PDF

Metal mesh-assisted CT localization of soft tissue foreign bodies for minimally invasive dermatological surgery.

J Am Acad Dermatol

January 2025

Department of Plastic Surgery, The Second Hospital & Clinical Medical School, Lanzhou University, Lanzhou 730030, Gansu, China. Electronic address:

View Article and Find Full Text PDF

Flexible tactile sensors have received significant attention for use in wearable applications such as robotics, human-machine interfaces, and health monitoring. However, conventional tactile sensors face challenges in accurately measuring pressure because vertical deformation is induced by Poisson's ratio in situations where lateral strain is applied. This study shows a strain-insensitive flexible tactile sensor array without the crosstalk effect using a highly stretchable mesh.

View Article and Find Full Text PDF

The discharge of oil-laden wastewater from industrial processes and the frequent occurrence of oil spills pose severe threats to the ecological environment and human health. Membrane materials with special wettability have garnered attention for their ability to achieve efficient oil-water separation by leveraging the differences in wettability at the oil-water interface. These materials are characterized by their simplicity, energy efficiency, environmental friendliness, and reusability.

View Article and Find Full Text PDF

This study investigates fixed and moving mesh methodologies for modeling liquid metal-free surface deformation during the induction melting process. The numerical method employs robust coupling of magnetic fields with the hydrodynamics of the turbulent stirring of liquid metal. Free surface tracking is implemented using the fixed mesh level set (LS) and the moving mesh arbitrary Lagrangian-Eulerian (ALE) formulation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!