Transcatheter Heart Valve Implantation in Bicuspid Patients with Self-Expanding Device.

Bioengineering (Basel)

Department for the Treatment and Study of Cardiothoracic Diseases and Cardiothoracic Transplantation, IRCCS-ISMETT, 90127 Palermo, Italy.

Published: July 2021

Bicuspid aortic valve (BAV) patients are conventionally not treated by transcathether aortic valve implantation (TAVI) because of anatomic constraint with unfavorable outcome. Patient-specific numerical simulation of TAVI in BAV may predict important clinical insights to assess the conformability of the transcathether heart valves (THV) implanted on the aortic root of members of this challenging patient population. We aimed to develop a computational approach and virtually simulate TAVI in a group of n.6 stenotic BAV patients using the self-expanding Evolut Pro THV. Specifically, the structural mechanics were evaluated by a finite-element model to estimate the deformed THV configuration in the oval bicuspid anatomy. Then, a fluid-solid interaction analysis based on the smoothed-particle hydrodynamics (SPH) technique was adopted to quantify the blood-flow patterns as well as the regions at high risk of paravalvular leakage (PVL). Simulations demonstrated a slight asymmetric and elliptical expansion of the THV stent frame in the BAV anatomy. The contact pressure between the luminal aortic root surface and the THV stent frame was determined to quantify the device anchoring force at the level of the aortic annulus and mid-ascending aorta. At late diastole, PVL was found in the gap between the aortic wall and THV stent frame. Though the modeling framework was not validated by clinical data, this study could be considered a further step towards the use of numerical simulations for the assessment of TAVI in BAV, aiming at understanding patients not suitable for device implantation on an anatomic basis.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8301021PMC
http://dx.doi.org/10.3390/bioengineering8070091DOI Listing

Publication Analysis

Top Keywords

thv stent
12
stent frame
12
valve implantation
8
patients self-expanding
8
aortic valve
8
bav patients
8
tavi bav
8
aortic root
8
aortic
6
thv
6

Similar Publications

Background: Computed tomography (CT) assessment is the standard for predicting coronary obstruction (CO) caused by sinus sequestration (SS) during transcatheter aortic valve (TAV) implantation in degenerated TAV (TAV-in-TAV) procedure, but it may not always be accurate. This report describes a prediction method for CO by using balloon aortic valvuloplasty (BAV) during TAV-in-TAV.

Case Summary: An 87-year-old woman with a history of balloon-expandable transcatheter heart valve (BE-THV) implantation 7 years prior was admitted with worsening dyspnoea.

View Article and Find Full Text PDF

Background: A dilated native right ventricular outflow tract (RVOT) presents unique challenges for transcatheter management using balloon-expandable valves. The Alterra Adaptive Prestent was designed to expand transcatheter therapy to treat patients with dilated RVOTs.

Objectives: The aim of this study was to report 2-year outcomes of the main cohort of the ALTERRA (Multicenter Study of Congenital Pulmonic Valve Dysfunction Studying the SAPIEN 3 THV With the Alterra Adaptive Prestent) pivotal trial using the prestent with transcatheter pulmonary valve replacement.

View Article and Find Full Text PDF

Background: Actual expansion of a transcatheter heart valve (THV) might differ from nominal, particularly during nonaortic valve-in-valve for a degenerated bioprosthetic surgical heart valve (SHV). This pilot study compared THV expansion measured using large-field-of-view intravascular ultrasound (IVUS) vs. multi-slice computed tomography (MSCT) and assessed the correlation between THV dimensions and transvalvular gradients.

View Article and Find Full Text PDF

Mechanical circulatory support (MCS) using veno-arterial extracorporeal membrane oxygenation (VA-ECMO) is widely implemented as a rescue device in transcatheter aortic valve implantation (TAVI). Although prophylactic VA-ECMO (pECMO) in TAVI is preferable to emergency VA-ECMO (eECMO) in terms of overall survival, there is currently no consensus on the introduction criteria for pECMO. Here, we report four cases of eECMO and pECMO performed in valve-in-valve TAVI (ViV-TAVI) with a small surgical bioprosthesis to consider the validity of the current pECMO indications.

View Article and Find Full Text PDF

Background: Asymmetrical expansion of transcatheter heart valves (THVs), manifesting as stent frame deformation, is an occasional fluoroscopic finding in transcatheter aortic valve replacement (TAVR).

Objectives: The aim of this study was to investigate the impact of asymmetrical expansion of balloon-expandable THVs on hemodynamic valve performance and clinical outcomes.

Methods: In a prospective registry, TAVR asymmetry index was measured using freeze-frame fluoroscopic images and was defined as the ratio of THV heights: [(longer height/shorter height) - 1] × 100.

View Article and Find Full Text PDF