Objective: To compare leakage pressures of colonic anastomoses performed with circular staplers to conventional hand-sewn techniques in dogs.
Study Design: Ex-vivo study.
Animals: Colon from 11 canine cadavers.
Methods: Thirty-two colonic anastomoses were performed. Four segments from each colon were randomly assigned to one of four techniques: hand-sewn colonic anastomoses performed with 4-0 glycomer 631 (G) and 4-0 barbed glycomer 631 (BG), and circular stapled colonic anastomoses using 4.8 mm End-to-End Anastomosis (EEA C4.8mm) and 3.5 mm End-to-End Anastomosis (EEA C3.5mm), 21 mm diameter circular staples in cadaveric canine colon. Leakage pressure was defined as the pressure at which dye-containing solution was first observed to leak from the anastomosis site.
Results: Leakage pressures were 49.5 mmHg (range:16-72) in group G, 45.5 mmHg (range:19-80) in group BG, 5.3 mmHg (range:0-31) in group C3.5mm, and 29.5 mmHg (range:23-50.3) in group C4.8mm. Anastomoses leaked at lower pressures when stapled rather than hand-sewn (C4.8mm-G p = .0313, C4.8mm-BG p = .0131, C3.5mm-G p = .0469, C3.5mm-BG p = .0313). Two of the C3.5mm constructs leaked immediately after saline infusion with 4/6 leaking at <5.3 mmHg.
Conclusion: End-to-end colonic anastomoses closed with circular stapler leaked at lower pressures than hand-sutured anastomoses. Use of the EEA stapler with a staple height of 3.5 mm did not result in safe colonic anastomoses.
Clinical Significance: These results provide evidence to support hand-suturing colonic anatomoses with G and BG in dogs. The 4.8 mm staples may be considered in anatomical locations difficult to reach.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/vsu.13705 | DOI Listing |
J Anus Rectum Colon
January 2025
Department of Gastroenterological Surgery, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan.
Objectives: To describe detailed surgical techniques for totally stapled intracorporeal anastomosis (TSIA) and determine their feasibility and safety by comparing short-term outcomes with those of conventional totally stapled extracorporeal anastomosis (TSEA).
Methods: In total, 59 consecutive patients who underwent laparoscopic colectomy between June 2018 and August 2021 were retrospectively assessed. Linear staplers were used for all anastomoses.
Tech Coloproctol
January 2025
Université Laval, 10, De l'Espinay St, Quebec City, QC, G1L 3L5, Canada.
Background: Inadequate bowel perfusion is among risk factors for colorectal anastomotic leaks. Perfusion can be assessed with indocyanine green fluorescence angiography (ICG) during colon resections. Possible benefits from its systematic use in high-risk patients with rectal cancer remain inconsistent.
View Article and Find Full Text PDFDis Colon Rectum
December 2024
Department of Colorectal Surgery, Cleveland Clinic, Ohio, United States.
Background: Deloyers technique addresses challenges in restoring bowel continuity following extended left hemicolectomies. Despite being first described in 1958, the technique remains underutilized, with limited data on long-term outcomes.
Objective: To evaluate the indications, surgical and functional outcomes of Deloyers technique and review existing literature.
BMC Surg
December 2024
AJA Universty of Medical Sciences, Tehran, Iran.
Background: Optimal selection of anastomosis technique is crucial in colectomy surgeries to ensure success and minimize postoperative complications. Various methods, both manual and stapler-assisted, are employed for intestinal anastomosis. This study aims to compare two surgical methods of intestinal anastomosis through macroscopic and microscopic examination.
View Article and Find Full Text PDFCommun Biol
December 2024
Laboratoire de Recherche en Imagerie du Vivant, PARCC, INSERM U970, Université Paris Cité, Paris, France.
Anastomotic leak occurrence is a severe complication after colorectal surgery. Considering the difficulty of treating these leaks and their impact on patient care, there is a strong need for an efficient prevention strategy. We evaluated a combination of extracellular vesicles (EVs) from rat adipose-derived stromal cells with a thermoresponsive gel, Pluronic® F127 (PF-127) to prevent anastomotic leaks.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!