A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

New Parameter of the Second Half of the P-Wave, P-Wave Duration, and Atrial Conduction Times Predict Atrial Fibrillation during Electrophysiological Studies. | LitMetric

Objective: Several P-wave parameters reflect atrial conduction characteristics and have been used to predict atrial fibrillation (AF). The aim of this study was to determine the relationship between maximum P-wave duration (PMax) and new P-wave parameters, with atrial conduction times (CT), and to assess their predictive value of AF during electrophysiological studies (AF-EPS).

Subjects And Methods: This was a cross-sectional study in 153 randomly selected patients aged 18-70 years, undergoing EPS. The patients were divided into 2 groups designated as no AF-EPS and AF-EPS, depending on whether AF occurred during EPS or not. Different P-wave parameters and atrial CT were compared for both study groups. Subsequently, the predictive value of the P-wave parameters and the atrial CT for AF-EPS was evaluated.

Results: The values of CT, PMax, and maximum Ppeak-Pend interval (Pp-eMax) were significantly higher in patients with AF-EPS. Almost all P-wave parameters were correlated with the left CT. PMax, Pp-eMax, and CT were univariate and multivariate predictors of AF-EPS. The largest ROC area was presented by interatrial CT (0.852; p < 0.001; cutoff value: ≥82.5 ms; sensitivity: 91.1%; specificity: 81.1%). Pp-eMax showed greater sensitivity (79.5%) to discriminate AF-EPS than PMax (72.7%), but the latter had better specificity (60.4% vs. 41.5%).

Conclusions: Left atrial CT were directly and significantly correlated with PMax and almost all the parameters of the second half of the P-wave. CT, PMax, and Pp-eMax (new parameter) were good predictors of AF-EPS, although CT did more robustly.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8562052PMC
http://dx.doi.org/10.1159/000518262DOI Listing

Publication Analysis

Top Keywords

p-wave parameters
20
atrial conduction
12
parameters atrial
12
p-wave
9
second half
8
half p-wave
8
p-wave duration
8
atrial
8
conduction times
8
predict atrial
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!