Estimation of occupational radiation doses in neuroendovascular procedures.

J Radiol Prot

Instituto Nacional de Neurología y Neurocirugía Manuel Velasco Suárez, CDMX 14269, Mexico.

Published: November 2021

To estimate the mean effective dose per procedure with multiple dosimetry, to calculate the annual effective dose to personnel working in neuroendovascular procedures and compared with methods reported in the literature and with national and international limits. The radiation dose to personnel was monitored in 20 procedures classified as diagnostic or therapeutic. During each procedure, the equivalent dose to eyes, thyroid, under and over the lead apron at chest level, hands, gonads and knees was measured with lithium fluoride thermoluminescent dosimeter chips (TLD-100). Estimations of the annual effective dose from different methods found in literature that use one or two dosimeters and from this work were compared. Also, a comparison was made with the safety limits recommended in national and international regulations. Radiation exposure to eyes, thyroid, gonads and knees is relevant to the effective dose, and therefore to the annual effective dose estimations. Personnel position is important, as the performing physician, who is closer to the patient, received the highest dose measured. In particular, this was observed in the equivalent dose received over the apron. However, the equivalent dose to the right eye was higher for neuroanaesthesiologists than for performing physicians due to their position relative to the patient. In general, effective doses estimated using one- and two-dosimeter methods found in the literature were, respectively, lower and higher than those obtained with the ten-dosimeter method in this work. The annual effective doses to personnel estimated with the multiple dosimetry algorithm ranged from 1.3 to 1.5 mSv yand are within the national and international limits.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1361-6498/ac1a83DOI Listing

Publication Analysis

Top Keywords

effective dose
20
annual effective
16
national international
12
equivalent dose
12
dose
10
neuroendovascular procedures
8
multiple dosimetry
8
dose personnel
8
international limits
8
eyes thyroid
8

Similar Publications

Photobiomodulation (PBM) is considered an effective and safe therapeutic modality in supporting the treatment of complications from a global pandemic-diabetes. In this study, PBM therapy is investigated to accelerate wound healing in diabetic mice (DM), under the combined biological effects of red light from a red organic light-emitting diode (ROLED) and near-infrared (NIR) light from an NIR conversion film (NCF) with dispersed CuInS/ZnS quantum dots (QDs). The QD concentration and the NCF structure were optimized to maximize the optical properties and mechanical stability.

View Article and Find Full Text PDF

Osteoarthritis (OA) is a chronic multifactorial disease characterized by cartilage degeneration, pain, and reduced mobility. Current therapies primarily aim to relieve pain and restore function, but they often have limited effectiveness and side effects. Coixol, a bioactive compound from Coix lacryma-jobi L.

View Article and Find Full Text PDF

Evaluation of a Deep Learning Denoising Algorithm for Dose Reduction in Whole-Body Photon-Counting CT Imaging: A Cadaveric Study.

Acad Radiol

January 2025

Department of Radiology, University Hospital Tuebingen, Hoppe-Seyler-Str. 3, 72076 Tuebingen, Germany (R.D., J.M.B., B.S., J.M., S.G., P.K., S.W., J.H., K.N., S.A., A.B.).

Rationale And Objectives: Photon Counting CT (PCCT) offers advanced imaging capabilities with potential for substantial radiation dose reduction; however, achieving this without compromising image quality remains a challenge due to increased noise at lower doses. This study aims to evaluate the effectiveness of a deep learning (DL)-based denoising algorithm in maintaining diagnostic image quality in whole-body PCCT imaging at reduced radiation levels, using real intraindividual cadaveric scans.

Materials And Methods: Twenty-four cadaveric human bodies underwent whole-body CT scans on a PCCT scanner (NAEOTOM Alpha, Siemens Healthineers) at four different dose levels (100%, 50%, 25%, and 10% mAs).

View Article and Find Full Text PDF

A polysaccharide from Morchella esculenta mycelia: Structural characterization and protective effect on antioxidant stress on PC12 cells against HO-induced oxidative damage.

Int J Biol Macromol

January 2025

State Key Laboratory of Food Nutrition and Safety, Tianjin University of Science and Technology, Tianjin 300457, PR China; State Key Laboratory of Food Nutrition and Safety, Ministry of Education, Tianjin University of Science and Technology, Tianjin 300457, PR China; College of Food Science and Engineering, Tianjin University of Science and Technology, Tianjin 300457, PR China. Electronic address:

Morchella esculenta (L.) Pers. is considered a precious edible and medicinal fungus due to its strict growth environment requirements, difficult to cultivate, resulted in expensive in the market.

View Article and Find Full Text PDF

Inverse dose protraction effects of high-LET radiation: evidence and significance.

Mutat Res Rev Mutat Res

January 2025

Radiation Epidemiology Branch, National Cancer Institute, MD 20892-9778, USA; Faculty of Health, Science and Technology, Oxford Brookes University, Headington Campus, OX3 0BP, UK.

Biological effects of ionizing radiation vary with radiation quality, which is often expressed as the amount of energy deposited per unit length, i.e., linear energy transfer (LET).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!