Extracorporeal membrane oxygenation (ECMO) is an invaluable means of supporting critically ill children with refractory respiratory or cardiac failure. Controversy remains; however, whether roller or centrifugal pumps are superior, particularly in infants. We performed a comprehensive search on PubMed, Embase, and Scopus for studies comparing the use of centrifugal and roller pumps in the pediatric and neonatal population from 1973 until March 1, 2020. All prospective and retrospective comparative studies were screened. Single-arm studies and those that included adult patients were excluded. The primary endpoint was survival to discharge. Secondary endpoints were complications (mechanical, cardiac, pulmonary, neurologic, renal, and hemolytic) and requirements for inotropic support. Random effects meta-analyses across all clinical endpoints were conducted. A total of four studies with 9111 patients were included. There was a statistically significant difference in in-hospital mortality, favoring the groups where roller pumps were used. Roller pumps were associated with fewer episodes of hemolysis, mechanical complications, cardiac complications, renal complications, and less inotropic support. ECMO with roller pumps may be associated with lower mortality in children. Roller pumps were associated with fewer complications, as well as reduced hemolysis and use of inotropes.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/MAT.0000000000001475 | DOI Listing |
Bioinspir Biomim
October 2024
Department of Biomedical Engineering, Seoul National University College of Medicine, 103, Daehak-ro, Jongno-gu, Seoul 03080, Republic of Korea.
Soft peristaltic pumps, which use soft ring actuators instead of mechanical pistons or rollers, offer advantages in transporting liquids with non-uniform solids, such as slurry, food, and sewage. Recent advances in 3D printing with flexible thermoplastic polyurethane (TPU) present the potential for single-step fabrication of these pumps, distinguished from handcrafted, multistep traditional silicone casting methods. However, because of the relatively high hardness of TPU, TPU-based soft peristaltic pumps contract insufficiently and thus cannot perform as well as silicone-based ones.
View Article and Find Full Text PDFArtif Organs
January 2025
Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, Maryland, USA.
Background: To accommodate a wider range of medical device sizes, a larger in vitro flow loop thrombogenicity test system using 9.5 -mm inner diameter (ID) tubing was developed and evaluated based on our previously established 6.4 -mm ID tubing system.
View Article and Find Full Text PDFSci Rep
June 2024
College of Mechanical and Electrical Engineering, Shihezi University, Shihezi, 832003, China.
Predicting and optimizing the mechanical performance of the helically wound nylon-reinforced rubber fertilizer hose (HWNR hose) is crucial for enhancing the performance of hose pumps. This study aims to enhance the service life of HWNR hoses and the efficiency of liquid fertilizer transport. First, a finite element simulation model and a mathematical model were established to analyze the influence of fiber layer arrangement on the maximum shear strain on the coaxial surface (MSS) and the reaction force on the extrusion roller (RF).
View Article and Find Full Text PDFHeliyon
March 2024
Department of Zoology, College of Science, King Saud University, P. O. Box 2455, Riyadh, 11451, Kingdom of Saudi Arabia.
Buckwheat is a globally recognized, nutritionally rich crop with robust adaptability, serving as a multi-purpose plant for its health benefits. Achieving precise and mechanized plot seed harvesting is a critical step in obtaining accurate results in breeding experiments. However, plot breeding requires no seed retention, no mixing, and ensures no accumulation of seed in the threshing unit.