Purpose: The purpose of this study was to compare the retinal vascular caliber of COVID-19 patients with that of healthy subjects.

Methods: This was a prospective case-control study. Forty-six patients who had COVID-19 were successfully treated, and 38 age- and gender-matched healthy subjects were enrolled in this study. Fundus photography was taken using fundus fluorescein angiography (FA; Visucam 500; Carl Zeiss Meditec, Jena, Germany). Retinal vascular caliber was analyzed with IVAN, a semi-automated retinal vascular analyzer (Nicole J. Ferrier, College of Engineering, Fundus Photography Reading Center, University of Wisconsin, Madison, WI, USA). Central retinal artery equivalent (CRAE), central retinal vein equivalent (CRVE), and artery-vein ratio (AVR) were compared between groups.

Results: The mean age was 37.8 ± 9.5 years in the COVID-19 group ( = 46) and 40 ± 8 years in the control group ( = 38) ( = 0.45). The mean CRAE was 181.56 ± 6.40 in the COVID-19 group and 171.29 ± 15.06 in the control group ( = 0.006). The mean CRVE was 226.34 ± 23.83 in the COVID-19 group and 210.94 ± 22.22 in the control group ( = 0.044). AVR was 0.81 ± 0.09 in the COVID-19 group and 0.82 ± 0.13 in the control group ( = 0.712).

Conclusion: Patients who had COVID-19 have vasodilation in the retinal vascular structure after recovery. As they may be at risk of retinal vascular disease, COVID-19 patients must be followed after recovery.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8280837PMC
http://dx.doi.org/10.1177/25158414211030419DOI Listing

Publication Analysis

Top Keywords

retinal vascular
24
covid-19 group
16
control group
16
patients covid-19
12
covid-19
9
retinal
8
vascular caliber
8
covid-19 patients
8
fundus photography
8
central retinal
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!