Objective:  This study aimed to evaluate implant-induced osteoporosis (IIO) development in toy breed dogs treated using internal fixation with digital radiographs as the index of pixel values.

Study Design:  There were 226 cases (236 limbs) of toy breed dogs with radial-ulnar fractures. Pixel values were measured on radiographs immediately, 2 weeks and 1 to 12 months after surgery. The ratio of pixel values (PVR) represented the bone mineral areal density based on the humeral condyle in the same image. The dogs were grouped based on the fixation methods, age and status of destabilization.

Results:  There was a significant decrease in the PVR at 1 to 12 months postoperatively for all cases. There were not any significant differences in PVR of antebrachial fractures between those repaired with plates using locking head screws, cortex screws or a combination of locking and cortex screws. Implant-induced osteoporosis persisted at 1 to 12 months postoperatively in dogs aged ≧6 months, while the PVR increased after 3 months in dogs aged <6 months. Based on the destabilization method, there was a significant increase in the PVR at 3 months in the plate removal group.

Conclusion:  This study suggests that IIO occurs in small dogs treated with plates and screws. Moreover, patients aged < 6 months showed an early postoperative recovery of bone mineral areal density. Further, screw and plate removal could contribute to the recovery of bone mineral areal density.

Download full-text PDF

Source
http://dx.doi.org/10.1055/s-0041-1731810DOI Listing

Publication Analysis

Top Keywords

implant-induced osteoporosis
12
toy breed
12
breed dogs
12
radial-ulnar fractures
8
dogs treated
8
pixel values
8
months postoperatively
8
cortex screws
8
dogs aged
8
dogs
6

Similar Publications

The use of uncemented stems in hip arthroplasty has been increasing, even in osteoporotic patients. The major concerns of uncemented hip-stems, however, are peri-prosthetic fracture, thigh pain, and proximal femoral stress-/strain-shielding. In this study, a novel design of uncemented hip-stem is proposed that will reduce such concerns, improve osseointegration, and benefit both osteoporotic and arthritic patients.

View Article and Find Full Text PDF

Objective:  The aim of this study was to evaluate the stress changes in the radii beneath the locking plates (LP) of dogs implanted with LP using finite element analysis (FEA).

Study Design:  The study included radii harvested from eight dogs. After computed tomography (CT) scans of the forelimb, the articular surface of the radius was fixed using resin.

View Article and Find Full Text PDF

Implant removal is unnecessary for biodegradable magnesium (Mg)-based implants and, therefore, the related risk for implant-induced fractures is limited. Aging, on the other hand, is associated with low bone-turnover and decreased bone mass and density, and thus increased fracture risk. Osteoporosis is accompanied by Mg deficiency, therefore, we hypothesized that Mg-based implants may support bone formation by Mg ion release in an ovariectomy-induced osteoporotic rat model.

View Article and Find Full Text PDF

Objective:  This study aimed to evaluate implant-induced osteoporosis (IIO) development in toy breed dogs treated using internal fixation with digital radiographs as the index of pixel values.

Study Design:  There were 226 cases (236 limbs) of toy breed dogs with radial-ulnar fractures. Pixel values were measured on radiographs immediately, 2 weeks and 1 to 12 months after surgery.

View Article and Find Full Text PDF

The aim of this study was to examine the effect of long-term locking plate fixation on the cortical bone of the canine radius. Locking compression plates were fixed to the left and right radius in dogs (n = 3). The left radius was fixed with a locking head screw (Locking Plate group, LP).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!