Unilateral cochlear implantation (CI) limits deafness-related changes in the auditory pathways but promotes abnormal cortical preference for the stimulated ear and leaves the opposite ear with little protection from auditory deprivation. In the present study, time-frequency analyses of event-related potentials elicited from stimuli presented to each ear were used to determine effects of unilateral CI use on cortical synchrony. CI-elicited activity in 34 adolescents (15.4±1.9 years of age) who had listened with unilateral CIs for most of their lives prior to bilateral implantation were compared to responses elicited by a 500Hz tone-burst in normal hearing peers. Phase-locking values between 4 and 60Hz were calculated for 171 pairs of 19-cephalic recording electrodes. Ear specific results were found in the normal hearing group: higher synchronization in low frequency bands (theta and alpha) from left ear stimulation in the right hemisphere and more high frequency activity (gamma band) from right ear stimulation in the left hemisphere. In the CI group, increased phase synchronization in the theta and beta frequencies with bursts of gamma activity were elicited by the experienced-right CI between frontal, temporal and parietal cortical regions in both hemispheres, consistent with increased recruitment of cortical areas involved in attention and higher-order processes, potentially to support unilateral listening. By contrast, activity was globally desynchronized in response to initial stimulation of the naïve-left ear, suggesting decoupling of these pathways from the cortical hearing network. These data reveal asymmetric auditory development promoted by unilateral CI use, resulting in an abnormally mature neural network.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.heares.2021.108308 | DOI Listing |
Neurosci Res
January 2025
Department of Cell Physiology, Graduate School of Medicine, Nagoya University, Nagoya 466-8550, Japan. Electronic address:
Sensorineural hearing loss causes cell death in central auditory neurons, but molecular mechanisms of triggering this process are not fully understood. We report here that loss of afferent activity promotes cell death by facilitating proBDNF-p75NTR signals in cochlear nucleus of chicks around hatch. RNA-seq analyses revealed up-regulation of genes related to proBDNF-p75NTR-JNK signals as well as apoptosis at the nucleus within 24hours after unilateral cochlea deprivation.
View Article and Find Full Text PDFAudiol Res
January 2025
Otolaryngology Unit, Department of Traslational Medicine and Neuroscience-DiBrain, University of Bari, 70124 Bari, Italy.
Aim: The aim of this study was to assess the subjective experiences of adults with different cochlear implant (CI) configurations-unilateral cochlear implant (UCI), bilateral cochlear implant (BCI), and bimodal stimulation (BM)-focusing on their perception of speech in quiet and noisy environments, music, environmental sounds, people's voices and tinnitus.
Methods: A cross-sectional survey of 130 adults who had undergone UCI, BCI, or BM was conducted. Participants completed a six-item online questionnaire, assessing difficulty levels and psychological impact across auditory domains, with responses measured on a 10-point scale.
Cureus
December 2024
Department of Otolaryngology, Manipal Hospital, Gurugram, IND.
Aims And Objectives: The study aimed to compare the auditory perception status of children from different socioeconomic backgrounds, specifically urban versus rural. It also examined the correlation between outcome measures and the frequency of auditory verbal therapy sessions attended, as well as the impact of continuous electric analog stimulation on the age of implantation.
Material And Methods: A retrospective cohort study was carried out on 30 children who have received unilateral cochlear implantation in rural versus urban backgrounds.
Int J Audiol
January 2025
Department of Otorhinolaryngology and Head & Neck Surgery, Leiden University Medical Center, Leiden, Netherlands.
Objective: Measuring listening effort using pupillometry is challenging in cochlear implant (CI) users. We assess three validated speech tests (Matrix, LIST, and DIN) to identify the optimal speech material for measuring peak-pupil-dilation (PPD) in CI users as a function of signal-to-noise ratio (SNR).
Design: Speech tests were administered in quiet and two noisy conditions, namely at the speech recognition threshold (0 dB re SRT), i.
Introduction: This study aims to investigate the impact of auditory input on postural control in young adult cochlear implant users with profound sensorineural hearing loss. The research explores the relationship between auditory cues and static postural stability in individuals with hearing impairment.
Methods: 34 young adult cochlear implant users, consisting of 15 males and 19 females aged 18-35 years, underwent various balance tests, including the modified Clinical Tests of Sensory Interaction on Balance (mCTSIB) and the Unilateral Stance Test (UST), under different auditory conditions: (1) White noise stimulus present with the sound processor activated, (2) Ambient noise present with the sound processor activated, and (3) Sound processor deactivated.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!