Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 144
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 144
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 212
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1002
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3142
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background And Purpose: Developing NTCP-models for cardiac complications after breast cancer (BC) radiotherapy requires cardiac dose-volume parameters for many patients. These can be obtained by using multi-atlas based automatic segmentation (MABAS) of cardiac structures in planning CT scans. We investigated the relevance of separate multi-atlases for deep inspiration breath hold (DIBH) and free breathing (FB) CT scans.
Materials And Methods: BC patients scanned in DIBH (n = 10) and in FB (n = 20) were selected to create separate multi-atlases consisting of expert panel delineations of the whole heart, atria and ventricles. The accuracy of atlas-generated contours was validated with expert delineations in independent datasets (n = 10 for DIBH and FB) and reported as Dice coefficients, contour distances and dose-volume differences in relation to interobserver variability of manual contours. Dependency of MABAS contouring accuracy on breathing technique was assessed by validation of a FB atlas in DIBH patients and vice versa (cross-validation).
Results: For all structures the FB and DIBH atlases resulted in Dice coefficients with their respective reference contours ≥ 0.8 and average contour distances ≤ 2 mm smaller than slice thickness of (CTs). No significant differences were found for dose-volume parameters in volumes receiving relevant dose levels (WH, LV and RV). Accuracy of the DIBH atlas was at least similar to, and for the ventricles better than, the interobserver variation in manual delineation. Cross-validation between breathing techniques showed a reduced MABAS performance.
Conclusion: Multi-atlas accuracy was at least similar to interobserver delineation variation. Separate atlases for scans made in DIBH and FB could benefit atlas performance because accuracy depends on breathing technique.