Nasopharyngeal sampling for nucleic acid amplification testing (NAAT) is the standard diagnostic test of coronavirus disease 2019. Our objectives were to assess, in real-life conditions, the diagnostic accuracy of a nasopharyngeal point-of-care antigen (Ag) test and of saliva NAAT for detection of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) in ambulatory care. This was a prospective cohort study from 19 October through 18 December 2020 in two community COVID-19 screening centers in Paris, France. Two nasopharyngeal swabs and one saliva sample were simultaneously collected. Diagnostic accuracies of nasopharyngeal Ag testing and of three saliva NAAT methods were assessed as compared to nasopharyngeal NAAT. A total of 1452 ambulatory children and adults were included. Overall, 129/1443 (9%) participants tested positive on nasopharyngeal NAAT (102/564 [18%] in symptomatic and 27/879 [3%] in asymptomatic participants). Sensitivity was 94%, 23%, 96%, and 94% for the three different protocols of saliva NAAT and for the nasopharyngeal Ag test, respectively. Estimates of specificity were above 95% for all methods. Diagnostic accuracy was similar in symptomatic and asymptomatic individuals. Diagnostic accuracy of nasopharyngeal Ag testing and of saliva NAAT is similar to that of nasopharyngeal NAAT, subject to compliance with specific protocols for saliva. Registration number: NCT04578509.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8329409 | PMC |
http://dx.doi.org/10.1007/s10096-021-04327-x | DOI Listing |
Viruses
July 2024
Department of Electrical Engineering and Computer Science, Florida Atlantic University, Boca Raton, FL 33431, USA.
The novel coronavirus SARS-CoV-2 was first isolated in late 2019; it has spread to all continents, infected over 700 million people, and caused over 7 million deaths worldwide to date. The high transmissibility of the virus and the emergence of novel strains with altered pathogenicity and potential resistance to therapeutics and vaccines are major challenges in the study and treatment of the virus. Ongoing screening efforts aim to identify new cases to monitor the spread of the virus and help determine the danger connected to the emergence of new variants.
View Article and Find Full Text PDFInt J Gen Med
July 2024
Department of Clinical Pathology, Faculty of Medicine Padjadjaran University/ Dr. Hasan Sadikin General Hospital, Bandung, West Java, Indonesia.
Introduction: Corona Virus Disease-19 (COVID-19) is a disease caused by Severe-Acute-Respiratory-Syndrome-Coronavirus-2 (SARS-CoV-2). The most reliable and widely accepted method for diagnosing this infection, despite facing various challenges, is the Reverse Transcription Polymerase Chain Reaction (RT-PCR) method, which utilizes nasopharyngeal swab sample. Reverse-transcription loop mediated isothermal amplification (RT-LAMP) is a simpler nucleic acid amplification method compared to the RT-PCR method.
View Article and Find Full Text PDFFront Epidemiol
January 2024
Department of Pediatrics, College of Medicine - Jacksonville, University of Florida, Jacksonville, FL, United States.
J Clin Microbiol
April 2024
Departments of Pathology and Laboratory Medicine and Pediatrics, Nationwide Children's Hospital, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA.
Human cytomegalovirus (CMV) is the leading cause of congenital infection worldwide and the most common cause of non-genetic sensorineural hearing loss. As there is no vaccine or other specific intervention to prevent congenital CMV infection, there is a need to identify maternal and congenital infections with sensitive and specific testing as early as possible. There is no widely accepted practice for screening during pregnancy or in all newborns for identification of possible cases of congenital CMV.
View Article and Find Full Text PDFAnal Chim Acta
January 2024
Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN, USA; Department of Public Health, Purdue University, West Lafayette, IN, USA. Electronic address:
Background: The COVID-19 pandemic has led to a rise in point-of-care (POC) and home-based tests, but concerns over usability, accuracy, and effectiveness have arisen. The incorporation of internal amplification controls (IACs), essential control for translational POC diagnostics, could mitigate false-negative and false-positive results due to sample matrix interference or inhibition. Although emerging POC nucleic acid amplification tests (NAATs) for detecting SARS-CoV-2 show impressive analytical sensitivity in the lab, the assessment of clinical accuracy with IACs is often overlooked.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!