Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To describe a new algorithm to measure corneal densitometry based on images obtained by swept source anterior segment ocular coherence tomography (SS-AS-OCT) and establish standard densitometry values in a group of normal eyes.
Methods: A total of 111 healthy participants (195 eyes) were enrolled in this study. Using a MATLAB designed algorithm, the cornea was segmented into three layers: anterior, posterior and mid-stroma, and it was divided into two concentric areas, 0-2 and 2-4 mm, resulting in nine areas for the analysis. The mean corneal densitometry values were calculated and expressed as grayscale units (GSU).
Results: The mean age was 57 years (range 22-87), with 100 (51.3%) right eyes and 95 (48.7%) left eyes. The total corneal densitometry was 86.9 ± 12.1 GSU. The mid-stroma layer had the highest densitometry values, 87.4 ± 12.1 GSU, and the anterior layer had the lowest values, 81.9 ± 14.2 GSU. Densitometry differences between the anterior layer and the mid-stroma layer (P < 0.001), as well as the anterior layer and the posterior layer (P < 0.05) were statistically significant. The 0-2 mm concentric area had higher mean densitometry values, 97.8 ± 12.7 GSU, and the differences were significant compared to the 2-4 mm concentric area (P < 0.001). No correlation was found between the corneal densitometry values and gender or age.
Conclusions: The new MATLAB segmentation algorithm for the analysis of corneal SS-AS-OCT images is capable to objectively assess corneal densitometry. We provide standard and normal data for better clinical and research approach.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9307768 | PMC |
http://dx.doi.org/10.1038/s41433-021-01707-7 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!