Background: Sufficient biofilm removal in the furcation area (FA) is a major challenge in the clinical practice of supportive periodontal therapy. The aim of the present experimental study was to simulate subgingival cleaning of the FA using a powered scaler (sonic scaler (AIR), ultrasonic scaler (US)) for conventional mechanical debridement versus two air polishing with nonabrasive powder (LAPA-1: glycine powder, LAPA-2: erythritol powder) and different nozzles for supra-/subgingival cleaning for each device.

Methods: Seven trained and calibrated operators with ≥ 2 years each of professional experience in treating periodontitis used the instruments to clean 3D-printed replicas of six molars with through-and-through FA (four 3-rooted and two 2-rooted teeth) in a manikin head. AIR and US were used in the control group; air polishing instruments were used in the test group. For reproducible evaluation, the test teeth were separated vertically into two or three parts, illuminated with ultraviolet light, photographed and evaluated planimetrically. Treatment time (TrT, in s) and relative cleaning efficacy (RCE, in %) were measured.

Results: Overall, 3-rooted molars (RCE in the entire FA, 23.19 ± 20.98%) could be cleaned significantly less effectively than 2-rooted molars (53.04 ± 28.45%, p < 0.001), regardless of the instrument used. In the cleaning of the entire FA, significantly higher RCE values were achieved with conventional mechanical debridement (AIR/US: 46.04 ± 25.96%/39.63 ± 22.02%; AIR vs. US: p > 0.05) than with air polishing (LAPA-1/LAPA-2: 34.06 ± 29.48%/17.09 ± 18.85%; LAPA-1 vs. LAPA-2: p < 0.001) regardless of whether a supra- or subgingival cleaning nozzle used (p < 0.001). Only LAPA-1 with a subgingival nozzle showed RCE values comparable to those of US (41.07 ± 28.95% vs. 39.63 ± 22.02%, p > 0.05). TrT was longest for US (299.40 ± 120.69 s) and shortest for LAPA-1 with a supragingival nozzle (129.67 ± 60.92 s, p < 0.001).

Conclusions: All of the examined instruments were effective to some degree in removing the simulated biofilm from the FA, but they differed substantially in cleaning efficacy. Only one air polishing device (LAPA-1) with a rigid subgingival nozzle was able to achieve RCE values similar to those of US. The current investigation confirmed that conventional mechanical debridement with powered scalers were most effective, but treatment took longer with these devices than air polishing.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8327450PMC
http://dx.doi.org/10.1186/s12903-021-01736-4DOI Listing

Publication Analysis

Top Keywords

air polishing
12
experimental study
8
subgingival cleaning
8
furcation area
8
air
5
study subgingival
4
cleaning
4
cleaning effectiveness
4
effectiveness furcation
4
area background
4

Similar Publications

Purpose: To assess the impact of anodization and instrumentation on titanium abutment surface characteristics (surface roughness and wettability) and biofilm formation (viability and mass).

Materials And Methods: Titanium discs were obtained from pre-milled abutment blanks made of titanium-6aluminum-7niobium alloy. Polished samples were divided into three groups: un-anodized, gold-anodized, and pink-anodized.

View Article and Find Full Text PDF

Van der Waals electrode integration is a promising strategy to create nearly perfect interfaces between metals and 2D materials, with advantages such as eliminating Fermi-level pinning and reducing contact resistance. However, the lack of a simple, generalizable pick-and-place transfer technology has greatly hampered the wide use of this technique. We demonstrate the pick-and-place transfer of prefabricated electrodes from reusable polished hydrogenated diamond substrates without the use of any sacrificial layers due to the inherent low-energy and dangling-bond-free nature of the hydrogenated diamond surface.

View Article and Find Full Text PDF

Ultra-High Sensitivity Methane Gas Sensor Based on Cryptophane-A Thin Film Depositing in Double D-Shaped Photonic Crystal Fiber Using the Vernier Effect.

Sensors (Basel)

December 2024

State Key Laboratory of Metastable Materials Science & Technology and Key Laboratory for Microstructural Material Physics of Hebei Province, School of Science, Yanshan University, Qinhuangdao 066004, China.

Methane gas leakage can lead to pollution problems, such as rising ambient temperature. In this paper, the Vernier effect of a double D-shaped photonic crystal fiber (PCF) in a Sagnac interferometer (SI) is proposed for the accurate detection of mixed methane gas content in the gas. The optical fiber structure of the effective sensing in the sensing SI loop and the effective sensing in the reference SI loop are the same.

View Article and Find Full Text PDF

Implant Surface Decontamination Methods That Can Impact Implant Wettability.

Materials (Basel)

December 2024

Department of Prosthodontics and Digital Technology, School of Dental Medicine, Stony Brook University, Stony Brook, NY 11794, USA.

This review addresses the effects of various decontamination methods on the wettability of titanium and zirconia dental implants. Despite extensive research on surface wettability, there is still a significant gap in understanding how different decontamination techniques impact the inherent wettability of these surfaces. Although the literature presents inconsistent findings on the efficacy of decontamination methods such as lasers, air-polishing, UV light, and chemical treatments, the reviewed studies suggest that decontamination alters in vitro hydrophilicity.

View Article and Find Full Text PDF

Gingival Margin Damage During Supragingival Dental Polishing by Inexperienced Operator-Pilot Study.

J Funct Biomater

December 2024

Department of Veterinary Anatomy, Histology and Embryology, Faculty of Veterinary Medicine, Trakia University, 6000 Stara Zagora, Bulgaria.

Background: Supragingival polishing is a crucial part of nonsurgical periodontal therapy. In recent years, air polishing has been used for this purpose, introducing different polishing powders. The purpose of the following study was to investigate the damage to the gingival margin during air polishing by an inexperienced operator.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!