Introduction: Locally advanced rectal cancer is often treated with neoadjuvant chemoradiotherapy and surgery. Radiotherapy carries significant risk of toxicity to organs at risk (OAR). Proton beam therapy (PBT) has demonstrated to be effective in other cancers, delivering equivalent dosimetric radiation but with the benefit of improved sparing of OAR. This review compares dosimetric irradiation of OAR and oncological outcomes for PBT versus conventional photon-based radiotherapy in locally advanced rectal cancer.
Methods: An electronic literature search was performed for studies with comparative cohorts receiving proton beam therapy and photon-based radiotherapy for rectal cancer.
Results: Eight articles with a total of 127 patients met the inclusion criteria. There was significantly less irradiated small bowel with PBT compared to three-dimensional conformal radiation therapy (3DCRT) and intensity-modulated radiation therapy (IMRT) (MD -17.01, CI [-24.06, -9.96], p < 0.00001 and MD -6.96, CI [-12.99, -0.94], p = 0.02, respectively). Similar dosimetric results were observed for bladder and pelvic bone marrow. Three studies reported clinical and oncological results for PBT in recurrent rectal cancer with overall survival reported as 43 %, 68 % and 77.2 %, and one study in primary rectal cancer with 100 % disease free survival.
Conclusion: PBT treatment plans revealed significantly less irradiation of OAR for rectal cancer compared to conventional photon-based radiotherapy. Trials for recurrent rectal cancer and PBT have shown promising results. There are currently no ongoing clinical trials for primary rectal cancer and PBT. More research is required to validate its potential role in dose escalation, higher complete response rate and organ preservation without increasing toxicity.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.suronc.2021.101638 | DOI Listing |
Sci Rep
January 2025
Nonprofitable Organization Touche NPO, Sapporo, 060-004, Japan.
In this study, we explore the structural intricacies of cellulose, a polymer composed of glucose monomers arranged in a linear chain, primarily investigated through solid-state NMR techniques. Specifically, we employ low-field proton nuclear magnetic resonance (H-NMR) to delve into the diverse hydrogen atom types within the cellulose molecule. The low-field H-NMR technique allows us to discern these hydrogen atoms based on their distinct chemical shifts, providing valuable insights into the various functional groups present in cellulose.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Biomedical and Biotechnological Sciences, University of Catania, 95123, Catania, Italy.
Recent investigations into radiation-induced side effects have focused on understanding the physiopathological consequences of irradiation on late-responding tissues like the spinal cord, which can lead to chronic progressive myelopathy. Proton therapy, an advanced radiation treatment, aims to minimize damage to healthy tissues through precise dose deposition. However, challenges remain, particularly regarding the variation in dose distribution, characterized by maximum deposition at the end of the proton range, known as the distal fall-off of a spread-out Bragg peak.
View Article and Find Full Text PDFMed Dosim
January 2025
Department of Radiation Oncology, Peking University First Hospital, Beijing, China. Electronic address:
This study presents a patient with a PET-CT detected residual lacrimal sac tumor who was treated with intensity modulated proton therapy (IMPT) and concurrent chemotherapy. The patient a 49-year-old male diagnosed with squamous cell carcinoma of the left lacrimal sac had under-went endoscopic surgery. Postoperative PET-CT implied tumor residual in the left lacrimal sac.
View Article and Find Full Text PDFPhys Med Biol
January 2025
Industrial Engineering, Universita degli Studi di Roma Tor Vergata, Via del Politecnico,1, Roma, 00133, ITALY.
The increasing interest in hadron therapy has heightened the need for accurate and reliable methods to assess radiation quality and the biological effectiveness of particles used in treatment. Microdosimetry has emerged as a key tool for this, demonstrating its potential, reliability, and suitability. In this context, solid-state microdosimeters offer technological advantages over traditional Tissue-Equivalent Proportional Counters, and recent advancements have further improved their performance and reliability.
View Article and Find Full Text PDFJ Radiat Res
January 2025
Department of Radiation Oncology, Southern Tohoku Proton Therapy Center 7-172, Yatsuyamada, Koriyama, Fukushima 963-8052, Japan.
This retrospective study aimed to compare the clinical outcomes of intensity-modulated radiation therapy (IMRT) and proton beam therapy (PBT). A total of 606 patients diagnosed with prostate cancer between January 2008 and December 2018 were included. Of these patients, 510 received PBT up to a dose of 70-78 Gy (relative biological effectiveness) and 96 patients received IMRT up to a dose of 70-78 Gy.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!