Purpose: To assess the convergent validity of body worn wearable camera (WC) still-images (IMGs) for determining posture compared with activPAL (AP) classifications.

Methods: Participants (n=16, mean age 46.7±23.8yrs, 9F) wore an Autographer WC above the xyphoid process and an AP during three, 2hr free-living visits. IMGs were captured on average 8.47 seconds apart and were annotated with output consisting of events, transitory states, unknown and gaps. Events were annotations that matched AP classifications (sit, stand and move) consisting of at least 3 IMGs, transitory states were posture annotations fewer than 3 IMGs, unknown were IMGs that could not be accurately classified, and gaps were time between annotations. For analyses, annotation and AP output were converted to one-sec epochs and matched second-by-second. Total and average length of visits and events are reported in minutes. Bias and 95% CIs for event posture times from IMGs to AP posture times were calculated to determine accuracy and precision. Confusion matrices using total AP posture times were computed to determine misclassification.

Results: 43 visits were analyzed with a total visit and event time of 5027.73 and 4237.23 minutes and average visit and event lengths being 116.92 and 98.54 minutes, respectively. Bias was not statistically significant for sitting but significant for standing and movement (0.84, -6.87 and 6.04 minutes). From confusion matrices, IMGs correctly classified sitting, standing and movement 85.69%, 54.87%, and 69.41% of total AP time, respectively.

Conclusion: WC IMGs provide a good estimation of overall sitting time but underestimate standing and overestimate movement time. Future work is warranted to improve posture classifications and examine IMG accuracy and precision in assessing activity type behaviors.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8320753PMC
http://dx.doi.org/10.1123/jmpb.2020-0038DOI Listing

Publication Analysis

Top Keywords

posture times
12
wearable camera
8
imgs
8
transitory states
8
minutes bias
8
accuracy precision
8
confusion matrices
8
visit event
8
sitting standing
8
standing movement
8

Similar Publications

Polysomnographic Phenotype of Positional Obstructive Sleep Apnea.

J Rhinol

November 2024

Department of Otorhinolaryngology-Head and Neck Surgery, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.

Background And Objectives: Obstructive sleep apnea (OSA) is a prevalent sleep disorder characterized by recurrent upper airway obstruction, leading to disrupted sleep and various health complications. Positional OSA (POSA) refers to patients whose OSA severity is significantly influenced by body position, especially when lying supine. This study aimed to evaluate the polysomnographic characteristics of POSA and non-positional OSA (non-POSA) and to assess their clinical implications.

View Article and Find Full Text PDF

Introduction: The diagnosis of diseases known as synucleinopathies, Parkinson's disease (PD), multiple system atrophy (MSA) and Lewy body dementia (DLB), is predominantly based on clinical criteria. However, diagnostic uncertainty may persist until late in the disease process leading to delays in diagnosis and medical mismanagement. Skin biopsy detection of phosphorylated alpha-synuclein (P-SYN) is a sensitive and specific technique that increases diagnostic sensitivity of synucleinopathies, although the clinical utility of this test has not been fully explored.

View Article and Find Full Text PDF

Validation of Devices for the Five Times Sit To Stand Test: Comparing Plantar Pressure and Head Motion Analysis with Manual Measurement.

Yonsei Med J

January 2025

Department of Rehabilitation Medicine, Rehabilitation Institute of Neuromuscular Disease, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea.

Purpose: This study aims to evaluate a new method for the five times sit to stand test (FTSST), crucial for addressing frailty in an aging population. It utilizes a smart insole for plantar pressure analysis and a marker-less motion capture device for head height analysis.

Materials And Methods: Thirty-five participants aged 50 years or older underwent FTSST assessment using three methods: manual measurement with a stopwatch (FTSST-M), plantar pressure analysis with smart insoles (FTSST-P), and head height analysis with a marker-less motion capture device (FTSST-H).

View Article and Find Full Text PDF

Online control ability affects precision fitting performances of long-term Tai Chi practitioners in older adults.

Gait Posture

December 2024

Department of Health Science and Kinesiology, Georgia Southern University, Statesboro, USA. Electronic address:

Background: Age-related decline in goal-directed behavior could be risky for older adults to maintain daily activities. Our previous studies have shown that long-term Tai Chi (TC) practice could improve motor performance and postural control during goal-directed tasks. However, there was a paucity of studies examining TC's effects on online control of goal-directed action.

View Article and Find Full Text PDF

Accurate calving time prediction plays a critical role in ensuring the well-being of both mother and calf during parturition. Challenges during the calving process, particularly in abnormal cases, often necessitate human intervention to prevent potentially fatal outcomes. This study proposes a novel system for automated prediction of normal and abnormal cattle calving cases based on posture analysis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!