Objective: Different techniques of performing image-guided neurosurgery exist, namely, neuronavigation systems, intraoperative ultrasound, and intraoperative MRI, each with its limitations. Except for ultrasound, other methods are expensive. Three-dimensional virtual reconstruction and surgical simulation using 3D volume rendering (VR) is an economical and excellent technique for preoperative surgical planning and image-guided neurosurgery. In this article, the authors discuss several nuances of the 3D VR technique that have not yet been described.
Methods: The authors included 6 patients with supratentorial gliomas who underwent surgery between January 2019 and March 2021. Preoperative clinical data, including patient demographics, preoperative planning details (done using the VR technique), and intraoperative details, including relevant photos and videos, were collected. RadiAnt software was used for generating virtual 3D images using the VR technique on a computer running Microsoft Windows.
Results: The 3D VR technique assists in glioma surgery with a preoperative simulation of the skin incision and craniotomy, virtual cortical surface marking and navigation for deep-seated gliomas, preoperative visualization of morbid cortical surface and venous anatomy in surfacing gliomas, identifying the intervenous surgical corridor in both surfacing and deep-seated gliomas, and pre- and postoperative virtual 3D images highlighting the exact spatial geometric residual tumor location and extent of resection for low-grade gliomas (LGGs).
Conclusions: Image-guided neurosurgery with the 3D VR technique using RadiAnt software is an economical, easy-to-learn, and user-friendly method of simulating glioma surgery, especially in resource-constrained countries where expensive neuronavigation systems are not readily available. Apart from cortical sulci/gyri anatomy, FLAIR sequences are ideal for the 3D visualization of nonenhancing diffuse LGGs using the VR technique. In addition to cortical vessels (especially veins), contrast MRI sequences are perfect for the 3D visualization of contrast-enhancing high-grade gliomas.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3171/2021.5.FOCUS21236 | DOI Listing |
Med Biol Eng Comput
January 2025
Mechanical Engineering Department, Tianjin University, No. 135, Yaguan Road, Haihe Education Park, Jinnan District, Tianjin City, 300350, China.
The use of AR technology in image-guided neurosurgery enables visualization of lesions that are concealed deep within the brain. Accurate AR registration is required to precisely match virtual lesions with anatomical structures displayed under a microscope. The purpose of this work was to develop a real-time augmented surgical navigation system using contactless line-structured light registration, microscope calibration, and visible optical tracking.
View Article and Find Full Text PDFEur J Neurol
January 2025
Department of Neurosurgery, Medical University of Vienna, Vienna, Austria.
Background: Temporal lobe epilepsy (TLE) can lead to structural brain abnormalities, with thalamus atrophy being the most common extratemporal alteration. This study used probabilistic tractography to investigate the structural connectivity between individual thalamic nuclei and the hippocampus in TLE.
Methods: Thirty-six TLE patients who underwent pre-surgical 3 Tesla magnetic resonance imaging (MRI) and 18 healthy controls were enrolled in this study.
World Neurosurg
January 2025
Bhabha Atomic Research Centre, Mumbai, India-400085.
This paper deals with neuro-registration using tele-manipulation (Master-Slave Manipulation) to facilitate tele-surgery and enhance the overall accuracy and reach of the robot-assisted neurosurgery. Accurate Neuro-registration is important as the success of the surgical procedure highly depends on it. A 6-degree-of-freedom Parallel Kinematic Mechanism (6D-PKM) master-slave robot in tele-manipulation mode is utilized for both neuro-registration and neurosurgery.
View Article and Find Full Text PDFNeuroimage
January 2025
Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minneapolis, USA.
Introduction: Ultra-high-field magnetic resonance (MR) systems (7 T and 9.4 T) offer the ability to probe human brain metabolism with enhanced precision. Here, we present the preliminary findings from 3D MR spectroscopic imaging (MRSI) of the human brain conducted with the world's first 10.
View Article and Find Full Text PDFBiomed Eng Lett
January 2025
NaviNetics, Inc, Rochester, MN USA.
Stereotactic systems have traditionally used Cartesian coordinate combined with linear algebraic mathematical models to navigate the brain. Previously, the development of a novel stereotactic system allowed for improved patient comfort, reduced size, and carried through a simplified interface for surgeons. The system was designed with a work envelope and trajectory range optimized for deep brain stimulation applications only.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!