The kinetics, in vivo distribution and sites of sequestration of autologous In-111-labelled platelets and other platelet function parameters were studied in ten patients with type IIa or IIb familial hypercholesterolaemia and thrombotic complications of atherosclerosis. The in vitro platelet aggregation response to ADP (P = 0.50) and collagen (P = 0.46); binding of fibrinogen to platelets (P = 0.61); and plasma beta-thromboglobulin levels (P = 0.42) of the patients and normal reference subjects did not differ significantly. The in vivo distribution of In-111-labelled platelets at equilibrium was within normal limits, and at the end of platelet life-span the sequestration pattern of labelled platelets in the reticuloendothelial system was also normal (spleen P = 0.31; liver P = 0.54). There was minimal evidence of in vivo platelet activation: only mean platelet lifespan (MPLS), 195 +/- 57 hours (difference between mean MPLS of patients and controls was 25 hours, with a 95% confidence interval from 23 to 31 hours; P = 0.02); mean platelet platelet turnover, 2298 +/- 824 platelets/microliter/hour (P = 0.005); plasma platelet factor 4 (P = 0.02); and the mean circulating platelet aggregate ratio, 0.8 +/- 0.1 (P = 0.02); differed significantly from normal. These results suggest that abnormalities of platelet function and kinetics observed in type II hyperlipoproteinaemia cannot be ascribed wholly to the hyperlipidaemia, but may be induced by the associated atherosclerosis.
Download full-text PDF |
Source |
---|
Comput Med Imaging Graph
January 2025
CAS Key Laboratory of Molecular Imaging, Institute of Automation, Chinese Academy of Sciences, Beijing 100190, China; School of Artificial Intelligence, University of Chinese Academy of Sciences, Beijing 100049, China; National Key Laboratory of Kidney Diseases, Beijing 100853, China. Electronic address:
In clinical optical molecular imaging, the need for real-time high frame rates and low excitation doses to ensure patient safety inherently increases susceptibility to detection noise. Faced with the challenge of image degradation caused by severe noise, image denoising is essential for mitigating the trade-off between acquisition cost and image quality. However, prevailing deep learning methods exhibit uncontrollable and suboptimal performance with limited interpretability, primarily due to neglecting underlying physical model and frequency information.
View Article and Find Full Text PDFAdv Sci (Weinh)
January 2025
Discovery Biology, Discovery Sciences, BioPharmaceuticals R&D, AstraZeneca, Pepparedsleden 1, Mölndal, 43150, Sweden.
Targeted delivery of therapeutic agents is a persistent challenge in modern medicine. Recent efforts in this area have highlighted the utility of extracellular vesicles (EVs) as drug carriers, given that they naturally occur in bloodstream and tissues, and can be loaded with a wide range of therapeutic molecules. However, biodistribution and tissue tropism of EVs remain difficult to study systematically.
View Article and Find Full Text PDFJ Biomed Opt
January 2025
University of Ljubljana, Faculty of Mathematics and Physics, Ljubljana, Slovenia.
Significance: Machine learning models for the direct extraction of tissue parameters from hyperspectral images have been extensively researched recently, as they represent a faster alternative to the well-known iterative methods such as inverse Monte Carlo and inverse adding-doubling (IAD).
Aim: We aim to develop a Bayesian neural network model for robust prediction of physiological parameters from hyperspectral images.
Approach: We propose a two-component system for extracting physiological parameters from hyperspectral images.
Cancer Med
January 2025
Clinical Research Center, Beijing Children's Hospital, Capital Medical University, Beijing, China.
Background: 7-Hydroxymethotrexate (7-OHMTX) is the main metabolite in plasma following high-dose MTX (HD-MTX), which may result in activity and toxicity of the MTX. Moreover, 7-OHMTX could produce crystalline-like deposits within the renal tubules under acidic conditions or induce renal inflammation, oxidative stress, and cell apoptosis through various signaling pathways, ultimately leading to kidney damage. The objectives of this study were thus to explore the exposure-safety relationship of two compounds and search the most reliable marker for predicting HDMTX nephrotoxicity.
View Article and Find Full Text PDFWorld J Urol
January 2025
Division of Urology, University of Montreal Hospital Center, Montreal, Canada.
Purpose: To report on in-vivo intrarenal pressure (IRP) during flexible ureteroscopy for treatment of kidney stones while using the novel flexible and navigable suction ureteral access sheath (FANS).
Methods: A retrospective observational analysis was performed for 25 patients undergoing routine flexible ureteroscopy for treatment of renal stones between February 2024 and June 2024 from two centres in Canada. The LithoVue Elite™ ureteroscope (Boston Scientific Corp.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!