Protein concentration is an important attribute in the production of subunit or component-based vaccine antigens. Rigorous monitoring of protein concentration is required to identify potential areas for yield improvement. The current GMP method for quantitation is the plate-based ELISA which requires numerous hands-on steps and has low sensitivity in comparison to new microfluidic systems. To address this issue, a sensitive automated microCapillary Electrophoresis ImmunoAssay (mCE IA) method was developed to accurately separate and quantitate pertactin (PRN), an important antigen of the modern acellular Pertussis (aP) vaccine. PRN is reported to be a low-yielding antigen; thus, it is critical to observe its concentration throughout its manufacturing process. First, a primary antibody for PRN was identified to establish suitable immunoprobing conditions for detection of PRN over a wide linear dynamic range that spans 3 orders of magnitude. Next, the pre-adsorbed PRN Drug Substance (DS) was used as a reference standard to quantitate PRN samples against a calibration curve with adequate accuracy and precision. Four representative samples including three in-process steps and final adjuvanted drug product: Quadracel®, were examined to demonstrate the capability of mCE IA to quantitate PRN with high sensitivity and specificity. The matrices of the selected samples contain additional components (e.g. other proteins, growth factors, cell culture media, residual ammonium sulfate, and aluminum adjuvant) often making the quantitation of PRN challenging. The specificity and method linearity were demonstrated by spiking pre-adsorbed PRN DS into the four representative samples. In addition, it was shown that reportable concentrations of PRN for nine downstream process steps as analyzed by our method is comparable to concentrations obtained with ELISA. Most importantly, this study demonstrated that our method's quantitative accuracy is independent of matrix components, as each sample undergoes extensive dilution. This allows for seamless end-to-end analysis of PRN from fermenter harvest, through to complex downstream process samples to adjuvanted drug products. Finally, for the first time the developed and qualified mCE IA method was shown to quantify PRN throughout the entire manufacturing process to provide rapid feedback for process optimizations allowing for accurate yield and step-loss calculations.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jpba.2021.114284 | DOI Listing |
Brain Commun
January 2025
Translational Neuroimaging Laboratory, McGill University Research Centre for Studies in Aging, Montreal, QC, Canada H4H 1R2.
Blood-based biomarkers have been revolutionizing the detection, diagnosis and screening of Alzheimer's disease. Specifically, phosphorylated-tau variants (p-tau, p-tau and p-tau) are promising biomarkers for identifying Alzheimer's disease pathology. Antibody-based assays such as single molecule arrays immunoassays are powerful tools to investigate pathological changes indicated by blood-based biomarkers and have been studied extensively in the Alzheimer's disease research field.
View Article and Find Full Text PDFPediatr Emerg Care
January 2025
From the Medical University of South Carolina, Pharmacy Services, Charleston, SC.
Objectives: In the treatment of agitation in a pediatric emergency department (PED), it is common to use once or as needed (PRN) medications when nonpharmacological management options have failed. Currently, there is limited available evidence on the treatment of pediatric agitation. The objective of this analysis was to characterize the prescribing practices of once or PRN medications for the treatment of agitation in a PED at an academic medical center.
View Article and Find Full Text PDFBMC Psychiatry
January 2025
Department of Psychiatry, Kitasato University, School of Medicine, 1-15-1 Kitasato, Minami-Ku, Sagamihara, Kanagawa, 252-0374, Japan.
Background: Pro re nata (PRN) medication is used "as needed" for symptoms such as agitation and insomnia, in addition to regular daily pharmacotherapy of mental disorders. However, there is no high-quality evidence on the effectiveness of psychotropic PRN medications and concerns have been raised about their potential to contribute to polypharmacy. This study introduced a psychotropic PRN prescription-monitoring programme for psychiatric inpatients with the aim of examining the change before and after the implementation of the programme.
View Article and Find Full Text PDFPlant Dis
January 2025
Clemson University, Entomology, Soils, and Plant Sciences, 120 Long Hall, Clemson, South Carolina, United States, 29634-0315;
Howler EVO is a biological fungicide based on metabolites of the bacterium Pseudomonas chlororaphis strain AFS009. One of the metabolites, pyrrolnitrin (PRN), is a chemical analogue of the phenylpyrrole fludioxonil used to manage gray mold of fruit crops caused by Botrytis cinerea. Resistance to fludioxonil in B.
View Article and Find Full Text PDFMicromachines (Basel)
November 2024
Key Laboratory of Rapid Development & Manufacturing Technology for Aircraft, Shenyang Aerospace University, Ministry of Education, Shenyang 110136, China.
In Ti-6Al-4V titanium alloy micro-machining, since the uncut chip thickness (UCT) is comparable to the radius of the tool cutting edge, there exists a minimum uncut chip thickness (MUCT), and when the UCT is smaller than the MUCT, the plowing effect dominates the cutting process, which seriously affects the machined surface quality and tool life. Therefore, the reliable prediction of the MUCT is of great significance. This paper used Deform to establish an orthogonal cutting simulation model, studied the effect of the dead metal zone (DMZ) on the micro-cutting material flow, determined the DMZ range, and proposed a new method for determining the MUCT based on the DMZ.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!