Comparing JM-105 and MBJ-20 Transcutaneous Bilirubinometers According to the Area Tested in Ethnically Diverse Late-Preterm and Term Neonates.

J Perinat Neonatal Nurs

Department of Women's & Newborn Health, Westmead Hospital, Westmead, New South Wales, Australia (Dr Khajehei, Dr Chua, and Mss Gidaszewski and Swain); Westmead Clinical School, The University of Sydney, Sydney, New South Wales, Australia (Dr Khajehei and Ms Gidaszewski); University of New South Wales, Sydney, New South Wales, Australia (Dr Khajehei); and Western Sydney University, Sydney, New South Wales, Australia (Dr Chua).

Published: October 2021

This study aims to evaluate the correlation between the results of transcutaneous bilirubin (TcB) levels measured by the 2 transcutaneous bilirubinometers according to the area tested and to compare the TcB measurements and the serum bilirubin (SBR) levels. We screened 78 neonates born at more than 35 weeks of gestation and aged less than 168 hours for jaundice. We used JM-105 and MBJ-20 to measure the TcB at the forehead and the chest. For newborns who had high TcB measurements, we obtained blood samples during the subsequent 30 minutes. There was a strong correlation between the TcB measurements by JM-105 and MBJ-20 and this correlation was stronger when they were used on the sternum. The mean differences between the TcB measurements on the forehead and the sternum and the SBR levels were similar for the JM-105 and the MBJ-20. There was a strong correlation between SBR and the measurements using the 2 devices on the sternum (JM-105: r = 0.805; MBJ-20: r = 0.801), unlike measurements taken on the forehead by each device (r = 0.777 and r = 0.751, respectively). Both devices had high sensitivity and negative predictive values at SBR level of less than 230 μmol/L (<13.4 mg/dL) and high specificity and positive predictive values at SBR level of 230 μmol/L and greater (>13.4mg/dL). Both devices equally overestimated the actual SBR and had more reliable results if used on the sternum.

Download full-text PDF

Source
http://dx.doi.org/10.1097/JPN.0000000000000555DOI Listing

Publication Analysis

Top Keywords

jm-105 mbj-20
16
tcb measurements
16
transcutaneous bilirubinometers
8
bilirubinometers area
8
area tested
8
sbr levels
8
strong correlation
8
measurements forehead
8
tcb
6
measurements
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!