Ratiometric fluorescence and smartphone dual-mode detection of glutathione using carbon dots coupled with Ag-triggered oxidation of o-phenylenediamine.

Nanotechnology

College of Chemistry and Materials Science, Anhui Key Laboratory of Chemo/Biosensing, The Key Laboratory of Functional Molecular Solids, Ministry of Education, Anhui Laboratory of Molecule-based Materials, Anhui Normal University, Wuhu 241000, People's Republic of China.

Published: August 2021

Developing ratiometric fluorescence and smartphone dual-mode bioanalysis methods is important but challenging. A ratiometric fluorescence method for determining glutathione (GSH) using carbon dots (CDs) and Ag-triggered o-phenylenediamine (OPD) oxidation is described here. Agoxidizes OPD to give 2,3-diaminophenazine (oxOPD), which effectively quenches CD fluorescence at 436 nm through the inner filter effect and causes a new emission peak at 561 nm. GSH chelates with Agand prevents the Agoxidizing OPD and therefore effectively preserves CD emission at 436 nm (blue) and allows only weak oxOPD fluorescence at 561 nm (orange) to occur. The oxOPD to CD fluorescence intensity ratio decreased linearly as the GSH concentration increased in the range 0-150 nM, and the detection limit was 15 nM. The ratiometric fluorescence probe lit with an ultraviolet lamp clearly changed color from orange to blue as the GSH concentration increased. An image was acquired using a smartphone camera and converted into digital values. The blue and red channel ratio was calculated and used to quantify GSH. The method therefore allows dual-mode detection of GSH.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1361-6528/ac1978DOI Listing

Publication Analysis

Top Keywords

ratiometric fluorescence
16
fluorescence smartphone
8
smartphone dual-mode
8
dual-mode detection
8
carbon dots
8
oxopd fluorescence
8
gsh concentration
8
concentration increased
8
fluorescence
6
gsh
6

Similar Publications

Background: Ochratoxin A (OTA) is toxic secondary metabolites produced by fungi and can pose a serious threat to food safety and human health. Due to the high stability and toxicity, OTA contamination in agricultural products is of great concern. Therefore, the development of a highly sensitive and reliable OTA detection method is crucial to ensure food safety.

View Article and Find Full Text PDF

A Spectroscopic Methodology to Early Detection of Urinary Tract Infections.

Sensors (Basel)

January 2025

Centro de Química Estrutural, Institute of Molecular Sciences, Departamento de Química e Bioquímica, Faculdade de Ciências, Universidade de Lisboa, Campo Grande, 1749-016 Lisboa, Portugal.

Healthcare-associated infections (HAI) are a critical public health problem, with 30 to 40% of infections related to the urinary tract system. These urinary tract infections (UTIs) are considered one of the most common microbial infections in hospital settings and everyday community contexts, where approximately 80% are highly correlated with urinary catheter insertion, i.e.

View Article and Find Full Text PDF

Ratiometric lanthanide coordination polymers (Ln-CPs) are advanced materials that combine the unique optical properties of lanthanide ions (e.g., Eu, Tb, Ce) with the structural flexibility and tunability of coordination polymers.

View Article and Find Full Text PDF

Environmental changes, such as applied medication, nutrient depletion, and accumulation of metabolic residues, affect cell culture activity. The combination of these factors reflects on the local temperature distribution and local oxygen concentration towards the cell culture scaffold. However, determining the temporal variation of local temperature, independent of local oxygen concentration changes in biological specimens, remains a significant technological challenge.

View Article and Find Full Text PDF

A fluorescent probe (NBC), constructed by benzothiazole-coumarin and naphthalimide derivatives, was developed for the detection of SO derivatives using the FRET (Förster Resonance Energy Transfer) strategy. NBC presented large Stokes shift (180 nm), fast response (2 min), high sensitivity (LOD: 45 nM) and an excellent linear relationship in response to SO derivatives. Moreover, NBC has been successfully applied to detect SO derivatives in food samples and living cells.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!