A novel macro-hybrid implant design was introduced to afford high apical primary stability and more coronal space to preserve the circumferential extraction socket architecture. This study presents 1-year data from a prospective single-arm cohort study. The data was distilled based on the following criteria: (1) single-tooth immediate tooth replacement therapy (ITRT) in the maxillary anterior and premolar regions in intact (Type 1) extraction sockets that were (2) treated with the dual-zone grafting technique. The clinical and radiographic outcomes of 48 ITRT implants were evaluated. The mean ± SD labial plate dimension changes were 0.33 ± 0.41 mm at the implant abutment interface (L1) and 0.34 ± 0.40 mm at 5.0 mm below (L2). The mean labial plate dimension (thickness) at the 1-year recall was 2.27 ± 0.88 mm (L1) and 1.95 ± 0.95 mm (L2). At ITRT, the ridge contour at the free gingival margin and 3.0 mm below it were 7.54 ± 0.93 mm and 9.44 ± 2.36 mm, respectively; after final restoration delivery, the corresponding values were 7.45 ± 0.95 mm and 10.23 ± 2.30 mm, respectively. The peri-implant soft tissue thickness (PISTT) at the time of implant-level impression-making was 3.29 ± 0.73 mm, with an average Pink Esthetic Score of 12.79. A macro-hybrid implant design showed high levels of primary stability (~60 Ncm), stable ridge contour at 1 year, a labial plate dimension between 1.5 and 2.0 mm, and PISTT > 3.0 mm, which may be a critical factor in providing stable, long-term esthetic outcomes.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.11607/prd.5709 | DOI Listing |
J Esthet Restor Dent
January 2022
Department of Periodontology, Columbia University College of Dental Medicine, New York, New York, USA.
The concept of immediate tooth replacement therapy (ITRT) in the esthetic zone has become a viable treatment modality and widely accepted in clinical practice. However, achieving adequate primary stability that enables immediate provisional restoration and desirable space for bone-grafting with conventional tapered body implant designs is challenging. The macro-hybrid implant design with a prosthetic angle correction and body-shift feature in a singular form provides not only greater primary stability of a wider diameter implant but also circumferential gap distance both facially and interproximally preserve the labial bone plate and interdental attachment apparatus of the adjacent natural teeth thereby maintaining the interdental papilla.
View Article and Find Full Text PDFInt J Periodontics Restorative Dent
August 2021
A novel macro-hybrid implant design was introduced to afford high apical primary stability and more coronal space to preserve the circumferential extraction socket architecture. This study presents 1-year data from a prospective single-arm cohort study. The data was distilled based on the following criteria: (1) single-tooth immediate tooth replacement therapy (ITRT) in the maxillary anterior and premolar regions in intact (Type 1) extraction sockets that were (2) treated with the dual-zone grafting technique.
View Article and Find Full Text PDFCompend Contin Educ Dent
May 2020
Clinical Professor, Director of Implant Dentistry, Columbia University College of Dental Medicine, New York, New York.
Background: A retrospective comparative radiographic and clinical studywas performed to evaluate primary stability, bone volume, and esthetic outcomes of tapered (T) implants (control group) versus inverted body-shift (INV) implants (test group).
Methods: A total of 42 platform-switched implants, 21 T and 21 INV, were used to replace nonrestorable teeth in maxillary central incisor post-extraction sockets. Implant primary stability and insertion torque values in addition to radiographic differences in labial plate dimension, tooth-to-implant distance, and marginal bone levels were correlated with clinical outcomes using the pink esthetic score (PES).
Extraction and immediate implant placement/restoration in the esthetic zone is clinically challenging; benefits include fewer surgical appointments and maintenance of peri-implant soft tissues throughout the treatment period, and limitations include gingival recession and bone dehiscence during surgery. Macro-hybrid implants (large-diameter apical/narrow-diameter occlusal) were placed in 19 patients immediately following the extraction of hopeless maxillary anterior teeth. Immediate restorations were fabricated without occlusal contacts.
View Article and Find Full Text PDFCompend Contin Educ Dent
October 2019
Clinical Professor, Department of Periodontology, Director of Implant Education, Columbia University, College of Dental Medicine, New York, New York.
An innovative macro hybrid implant design is aimed at enhancing labial plate dimension and tooth-implant distance while achieving consistent esthetic outcomes. This unique "body-shift" concept in diameter and shape combines a tapered apical portion with a cylindrical coronal portion in a singular implant body design. The overall configuration of the implant is inverted and "convergent" in form toward the implant-abutment interface where bone is thinnest.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!