  • The use of ultrasound mapping for vascular network assessment before and after arteriovenous fistula (AVF) implantation has become increasingly common in recent years.
  • Understanding key Doppler parameters and settings, such as the Doppler shift equation and artifact correction, is essential for accurate blood flow measurement.
  • Recent advancements in ultrasound technology allow for options ranging from portable to high-end systems, further enhancing vascular access evaluations.

Article Abstract

In the last years, the systematic use of ultrasound mapping of the upper limb vascular network before the arteriovenous fistula (AVF) implantation, access maturation, and clinical management of late complications is widespread and expanding. Therefore, a good knowledge of theoretical outlines, instrumentation, and operative settings is undoubtedly required for a thorough examination. In this review, the essential Doppler parameters, B-Mode setting, and Doppler applications are considered. Basic concepts on the Doppler shift equation, angle correction, settings on pulse repetition frequency, operative Doppler frequency, gain are reported to ensure adequate and correct sampling of blood flow velocity. A brief analysis of the Doppler inherent artefacts (as random noise, blooming, aliasing, and motion artefacts) and the adjustment setting to minimize or eliminate the confounding artefacts are also considered. Doppler aliasing occurs when the pulse repetition frequency is set too low. This artefact is particularly frequent in vascular access sampling due to the high velocities range registered in the fistula's different segments. Aliasing should be recognized because its correction is crucial to analyse the Doppler signals correctly. Recent advances in instrumentation are also considered about a potential purchase of a portable ultrasound machine or a top-of-line, high-end, or mid-range ultrasound system. Last, the pulse wave Doppler setting for vascular access B-Mode and Doppler assessment is summarized.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8607315PMC
http://dx.doi.org/10.1177/11297298211018060DOI Listing

Publication Analysis

Top Keywords

vascular access
12
doppler
10
pulse repetition
8
repetition frequency
8
basics performing
4
performing high-quality
4
high-quality color
4
color doppler
4
doppler sonography
4
vascular
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!