A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of Changes in PPV Using a Tidal Volume Challenge with a Passive Leg Raising Test to Predict Fluid Responsiveness in Patients Ventilated Using Low Tidal Volume. | LitMetric

Background: Tidal volume challenge pulse pressure variation (TVC-PPV) is considered one of the recent reliable dynamic indices of fluid responsiveness (FR); also, passive leg raising (PLR)-induced changes in cardiac output (CO) detected by echocardiography are considered a reliable reversible self-fluid challenge test; many patients share eligibility for both tests.

Objectives: The study aimed to compare the sensitivity and specificity of both tests for the prediction of FR in mechanically ventilated patients with hemodynamic instability.

Methods: We studied 46 patients. Hemodynamic parameters including PPV and CO (detected by velocity time integral (VTI) using echocardiography) recorded at tidal volume (VT) of 6 mL/kg/ideal body weight (IBW) in semi-recumbent position then recorded again after one-minute increase in TV from 6 to 8 mL/kg/IBW then recorded with PLR at TV of 6 mL/kg/IBW and finally with actual volume expansion in semi-recumbent position by 4 ml/kg bolus of crystalloid solution to define actual responders with increase of cardiac output of 15% or more.

Results: Sixteen patients were responders, and thirty patients were nonresponders; responders had significant increase in PPV with TVC 6 to 8 ml/kg/IBW with best cutoff value of 3.5 with a sensitivity of 93.8% and a specificity of 93.9%. PLR test-induced changes in CO had a sensitivity of 93.9% and a specificity of 86.7% with statistically best cutoff value of 6.5% increase in CO, but sensitivity was 75% at cutoff value of 10% increase in CO. Other parameters like PPV, PPV changes with PLR test, and PPV changes with fluid expansion were less sensitive indicators.

Conclusion: FR in patients with hemodynamic instability and mechanically ventilated with low tidal volume strategy can be efficiently predicted when PPV increases more than 3.5 with tidal volume challenge and when PLR induces 6.5% increase in CO monitored through VTI method by Doppler echocardiography, and both tests are equally reliable.

How To Cite This Article: Elsayed AI, Selim KAW, Zaghla HE, Mowafy HE, Fakher MA. Comparison of Changes in PPV Using a Tidal Volume Challenge with a Passive Leg Raising Test to Predict Fluid Responsiveness in Patients Ventilated Using Low Tidal Volume. Indian J Crit Care Med 2021;25(6):685-690.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8286417PMC
http://dx.doi.org/10.5005/jp-journals-10071-23875DOI Listing

Publication Analysis

Top Keywords

tidal volume
32
volume challenge
16
passive leg
12
leg raising
12
fluid responsiveness
12
ventilated low
12
low tidal
12
patients hemodynamic
12
volume
9
comparison changes
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!