Gait, the style of human walking, has been studied as a behavioral characteristic of an individual. Several studies have utilized gait to identify individuals with the aid of machine learning and computer vision techniques. However, there is a lack of studies on the nature of gait, such as the identification power or the uniqueness. This study aims to quantify the uniqueness of gait in a cohort. Three-dimensional full-body joint kinematics were obtained during normal walking trials from 488 subjects using a motion capture system. The joint angles of the gait cycle were converted into gait vectors. Four gait vectors were obtained from each subject, and all the gait vectors were pooled together. Two gait vectors were randomly selected from the pool and tested if they could be accurately classified if they were from the same person or not. The gait from the cohort was classified with an accuracy of 99.71% using the support vector machine with a radial basis function kernel as a classifier. Gait of a person is as unique as his/her facial motion and finger impedance, but not as unique as fingerprints.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8316524PMC
http://dx.doi.org/10.1038/s41598-021-94815-zDOI Listing

Publication Analysis

Top Keywords

gait vectors
16
gait
11
uniqueness gait
8
gait cohort
8
gait kinematics
4
kinematics cohort
4
cohort study
4
study gait
4
gait style
4
style human
4

Similar Publications

Ankle push-off is important for efficient, human-like walking, and many prosthetic devices mimic push-off using motors or elastic elements. The knee is extended throughout the stance phase and begins to buckle just before push-off, with timing being crucial. However, the exact mechanisms behind this buckling are still unclear.

View Article and Find Full Text PDF

Reliability of running gait variability measures calculated from inertial measurement units.

J Biomech

January 2025

Sport and Physical Activity Research Centre, Sheffield Hallam University, Olympic Legacy Park, 2 Old Hall Rd, Sheffield S9 3TY, United Kingdom. Electronic address:

Changes to the variability within biomechanical signals may reflect a change in the health of the human system. However, for running gait variability measures calculated from wearable device data, it is unknown whether a between-day difference reflects a shift in system dynamics reflective of a change in human health or is a result of poor between-day reliability of the measurement device or the biomechanical signal. This study investigated the reliability of stride time and sacral acceleration variability measures calculated from inertial measurement units (IMUs).

View Article and Find Full Text PDF

Background: An all-inside endoscopic flexor hallucis longus (FHL) tendon transfer is indicated for the treatment of chronic, full-thickness Achilles tendon defects. The aim of this procedure is to restore function of the gastrocnemius-soleus complex while avoiding the wound complications associated with open procedures.

Description: This procedure can be performed through 2 endoscopic portals, a posteromedial portal (the working portal) and a posterolateral portal (the visualization portal).

View Article and Find Full Text PDF

A valid novel ground reaction force distribution algorithm to determine midfoot kinetics of gait with a single force plate.

Gait Posture

December 2024

Marquette University, 1250 W. Wisconsin Ave, Milwaukee, WI 53233, United States; Shriners Children's Chicago, 2211 N. Oak Park Ave, Chicago, IL 60707, United States.

Background: Understanding midfoot joint kinetics is valuable for improved treatment of foot pathologies. Segmental foot kinetics cannot currently be obtained in a standard gait lab without the use of multiple force plates or a pedobarographic plate overlaid with a force plate due to the single ground reaction force (GRF) vector.

Research Question: Can an algorithm be created to distribute the GRF into multiple segmental vectors that will allow for calculation of accurate midfoot and ankle moments?

Methods: 20 pediatric subjects (10 typically developing, 10 with foot pathology) underwent multi-segment foot gait analysis using the Milwaukee Foot Model.

View Article and Find Full Text PDF

Background: Robot-Assisted Gait Rehabilitation (RAGR) is an established clinical practice to encourage neuroplasticity in patients with neuromotor disorders. Nevertheless, tasks repetition imposed by robots may induce boredom, affecting clinical outcomes. Thus, quantitative assessment of engagement towards rehabilitation using physiological data and subjective evaluations is increasingly becoming vital.

View Article and Find Full Text PDF