In analytical quality management, target setting models that are selected by the purpose together with the error models that are applied correctly have critical importance. In our study, we aimed to compare the analytical performance characteristics of routine clinical chemistry and immunoassay tests with different target-setting models proposed by various organizations. Our study was performed with internal and external quality control data obtained using Beckman Coulter AU680 for clinical chemistry analytes and Roche Cobas 8000 autoanalyzer for immunoassay analytes. The total analytical error (TAE) was calculated by the formula TAH%=1.65×(CV%)+Bias%. Measurement uncertainty (MU) has been calculated adhering to the Nordtest guideline. Results were compared with BVEFLM, CLIA, RCPA, PRDEQA%, pUEQAS%, and permissible MU (pU%) data to investigate analytical performance qualities. When we compare the results of TAE and MU, MU was found to be higher than TAE for all analytes. ALT, AST, glucose, K, and triglycerides ml target values, showing the best performance. Taken together, our results show that CLIA for total analytical error and PRDEQA% and pUEQAS% for measurement uncertainty can match better than BVEFLM, RCPA and pU%. These test results should be evaluated with measurement uncertainty to avoid misdiagnosis. Appropriate specification limits should be defined for the examination of test methods that meet the objectives for fitness for clinical purposes.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1080/00365513.2021.1955294 | DOI Listing |
Anal Bioanal Chem
January 2025
Statistical Engineering Division, National Institute of Standards and Technology, 100 Bureau Drive, Gaithersburg, MD, 20899-8980, USA.
Closely related species of Salmonidae, including Pacific and Atlantic salmon, can be distinguished from one another based on nucleotide sequences from the cytochrome c oxidase sub-unit 1 mitochondrial gene (COI), using ensembles of fragments aligned to genetic barcodes that serve as digital proxies for the relevant species. This is accomplished by exploiting both the nucleotide sequences and their quality scores recorded in a FASTQ file obtained via Next Generation (NextGen) Sequencing of mitochondrial DNA extracted from Coho salmon caught with hook and line in the Gulf of Alaska. The alignment is done using MUSCLE (Muscle 5.
View Article and Find Full Text PDFTechnology-facilitated abuse (TFA) describes the misuse or repurposing of digital systems to harass, coerce, or abuse. It is a global problem involving both existing and emerging technologies. Despite significant work across research, policy, and practice to understand the issue, the field operates within linguistic, conceptual, and disciplinary silos, inhibiting collaboration.
View Article and Find Full Text PDFBioelectromagnetics
January 2025
Seibersdorf Labor GmbH, Seibersdorf, Austria.
The electrical conductivity of human tissues is a major source of uncertainty when modelling the interactions between electromagnetic fields and the human body. The aim of this study is to estimate human tissue conductivities in vivo over the low-frequency range, from 30 Hz to 1 MHz. Noninvasive impedance measurements, medical imaging, and 3D surface scanning were performed on the forearms of ten volunteer test subjects.
View Article and Find Full Text PDFAnal Methods
November 2017
LGC Limited, Queens Road, Teddington, Middlesex TW11 0LY, UK.
The contribution of sampling to the combined uncertainty of measurement is assessed using a combination of literature review and experimental determination of sampling variability in a range of foodstuffs in order to determine whether there is a consistent relationship between analyte level and proportion of variation attributable to sampling. Experimental determinations used the duplicate method, an economical method of assessing the relative contributions of sampling and analytical variability to the overall variance of results. The experimental work covered sampling of retail foodstuffs.
View Article and Find Full Text PDFMem Cognit
January 2025
School of Interactive Computing, Georgia Institute of Technology, Atlanta, GA, USA.
Fifty years ago, Tversky and Kahneman (Cognitive Psychology, 5[2], 207-232, 1973) reported that people's speeded estimations of 8 × 7 × 6 × 5 × 4 × 3 × 2 × 1 were notably higher than their estimations for the equivalent expression in the opposite order, 1 × 2 × 3 × 4 × 5 × 6 × 7 × 8 (Median = 2,250 vs. 512, respectively). On top of this order effect, both groups grossly underestimated the correct value (40,320).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!