Percutaneous venopulmonary artery extracorporeal membrane oxygenation for right heart failure after left ventricular assist device insertion.

Interact Cardiovasc Thorac Surg

Hôpital Européen Georges Pompidou, Département de Chirurgie Cardio-vasculaire, Assistance Publique Hôpitaux de Paris, Paris, France.

Published: November 2021

Objectives: Right ventricular failure after left ventricular assist device (LVAD) insertion is associated with significant mortality and morbidity. Mechanical support options include right ventricular assist devices, venoarterial extracorporeal membrane oxygenation (ECMO) and venopulmonary artery ECMO, the latter often involving central cannulation. We sought to evaluate the feasibility and early outcomes of a truly percutaneous venopulmonary artery (pVPA) ECMO strategy, with the potential advantage of bedside removal once weaned.

Methods: Data from a single tertiary centre were reviewed retrospectively from January 2014 to January 2019. During this time, 54 patients underwent LVAD insertion, with 19 requiring mechanical support for right ventricular failure. Among them, 10 patients received pVPA ECMO. Implantation of the pVPA ECMO was performed under transoesophageal echocardiography and fluoroscopy guidance, with an inflow cannula placed in the right atrium via the right femoral vein and an outflow cannula placed in the left pulmonary artery (PA) via the right internal jugular vein.

Results: Cannula insertion was 100% successful with no need for repositioning. Eight patients (80%) were able to be successfully weaned (at the bedside); 6 were discharged from the hospital and there were no cases of early sepsis, mediastinitis or thromboembolism. At follow-up, 5 patients had received transplants (50%), with 1 on LVAD support as destination therapy (10%). Survival was 60 ± 15% and 50 ± 16% at 6 and 12 months, respectively.

Conclusions: pVPA ECMO is 100% technically feasible and is an efficient method for temporary right ventricular support after LVAD insertion with the advantage of simple bedside removal and avoidance of a PA graft remnant in the chest cavity.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8923379PMC
http://dx.doi.org/10.1093/icvts/ivab197DOI Listing

Publication Analysis

Top Keywords

pvpa ecmo
16
venopulmonary artery
12
ventricular assist
12
lvad insertion
12
percutaneous venopulmonary
8
extracorporeal membrane
8
membrane oxygenation
8
failure left
8
left ventricular
8
assist device
8

Similar Publications

Percutaneous venopulmonary artery extracorporeal membrane oxygenation for right heart failure after left ventricular assist device insertion.

Interact Cardiovasc Thorac Surg

November 2021

Hôpital Européen Georges Pompidou, Département de Chirurgie Cardio-vasculaire, Assistance Publique Hôpitaux de Paris, Paris, France.

Objectives: Right ventricular failure after left ventricular assist device (LVAD) insertion is associated with significant mortality and morbidity. Mechanical support options include right ventricular assist devices, venoarterial extracorporeal membrane oxygenation (ECMO) and venopulmonary artery ECMO, the latter often involving central cannulation. We sought to evaluate the feasibility and early outcomes of a truly percutaneous venopulmonary artery (pVPA) ECMO strategy, with the potential advantage of bedside removal once weaned.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!