Background: Primary and secondary implant stability is of high importance for survival and success of dental implants in the short and long term. Measurements of implant stability during healing provide the opportunity to monitor the course of the osseointegration process.

Purpose: To compare implant stability quotient (ISQ) by resonance frequency analysis (RFA), recorded with two different devices after implant placement.

Materials And Methods: Patients with the need of single tooth extraction in posterior sites of the maxilla and the mandible were treated in a surgical center. All patients received additional augmentation with a bovine bone substitute and platelet-rich fibrin (PRF) after atraumatic tooth extraction. After a healing period of 10 weeks, 28 self-tapping titanium-implants were placed. Implant stability was recorded with two different devices (Osstell and Penguin) at the time of implant insertion (T0), 10 days later (T1), and after 7 (T2), or 17 weeks (T3).

Results: No implant was lost, and no postoperative complication occurred during follow-up. Patient cohort comprised 9 female (32.1%) and 19 male patients (67.9%), with a mean age of 52.8 years, 64.3 years, respectively. Mean overall insertion torque was 43.6 Ncm at implant placement with no significant difference between implant location, age, or gender. No patient dropped out. During observation period, a significant increase in mean ISQ was recorded with both devices. Significant positive correlations between insertion torque and ISQ were recorded with both devices at T0, T2, and T3. No significant differences were observed in ISQ-values between both devices, and measuring directions at any point of measurement.

Conclusions: Within the limitations of this cohort study, both devices were suitable for RFA-measurement and revealed comparable results. Due to the cordless design, handling of the Penquin device was more comfortable. Reusability of the Penguin MultiPeg-transducers may offer an additional benefit with regard on ecological aspects.

Download full-text PDF

Source
http://dx.doi.org/10.1111/cid.13031DOI Listing

Publication Analysis

Top Keywords

implant stability
16
recorded devices
16
implant
10
resonance frequency
8
frequency analysis
8
implant placement
8
cohort study
8
tooth extraction
8
insertion torque
8
isq recorded
8

Similar Publications

Can robotic arm-assisted total knee arthroplasty be applied to valgus deformity.

Arch Orthop Trauma Surg

January 2025

Department of Orthopaedic Surgery, University Hospital centre (Saint Etienne), Avenue Albert Raimond, Saint-priest-en-Jarez, 42270, France.

Introduction: Total knee arthroplasty (TKA) in valgus knees is challenging. Optimal ligament balance, implant neutral or moderate valgus alignment are crucial but conventional instrumentations usually lead to outliers. Robotic arm assisted TKA (RATKA) advantages could answer this challenge.

View Article and Find Full Text PDF

Objective: To observe the clinical outcomes of anterior approach for the revision surgery following unsuccessful bone cement augmentation in osteoporotic vertebral compression fractures.

Methods: A total of 10 patients who experienced unsuccessful bone cement augmentation underwent anterior revision surgery between January 2020 and December 2021. There were 2 males and 8 females.

View Article and Find Full Text PDF

Stability Study of Anticoagulant Hydrogel Coatings Toward Long-Term Cardiovascular Devices.

Langmuir

January 2025

State Key Laboratory of Transvascular Implantation Devices, The Second Affiliated Hospital, School of Medicine, Zhejiang University, 88 Jiefang Road, Hangzhou 310009, P. R. China.

Implantable cardiovascular devices have revolutionized the treatment of cardiovascular diseases, yet their long-term functionality without causing thrombosis is a persistent challenge. Although the surface modification of anticoagulant coating has greatly improved the biocompatibility of the devices, its long-term stability in complex physiological environments still remains questionable. Herein, the stability of three anticoagulant hydrogel coatings, poly(2-methacryloyloxyethyl phosphorylcholine) (PMPC), poly(sodium 2-acryloyl-2-methylpropanesulfonate) (PAMPS), and poly(4-styrenesulfonate sodium) (PSS), is studied.

View Article and Find Full Text PDF

Miniaturization of next-generation active neural implants requires novel micro-packaging solutions that can maintain their long-term coating performance in the body. This work presents two thin-film coatings and evaluates their biostability and in vivo performance over a 7-month animal study. To evaluate the coatings on representative surfaces, two silicon microchips with different surface microtopography are used.

View Article and Find Full Text PDF

Implant-supported prosthetic rehabilitation for patients with severely atrophic jaws is challenging due to complex anatomical considerations and the limitations of conventional augmentation techniques. This study explores the potential of subperiosteal (juxta-osseous) implants as an alternative solution, using finite element analysis (FEA) to evaluate mechanical performance. Realistic jaw models, developed from radiographic data, are utilized to simulate various implant configurations and load scenarios.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!