Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background And Objective: When home non-invasive ventilation (NIV) is initiated, five goals need to be achieved: a daily use >4 h/day, an improvement in gas exchange, health-related quality of life (HRQL) and sleep quality without side effects. Our aim was to assess how frequently these five goals were reached and the factors predictive of achievement.
Methods: We conducted a monocentric cohort study that included patients electively established on home NIV over 2 years. HRQL was assessed at baseline and follow-up by the Severe Respiratory Insufficiency questionnaire. Adequate initiation was defined as the achievement of at least three of five goals and successful initiation as the achievement of all.
Results: Two-hundred and fifty patients were included at baseline. NIV was initiated for: obesity hypoventilation syndrome (n = 95; 38%), neuromuscular disease (n = 70; 28%), chronic obstructive pulmonary disease (n = 66; 26%) and chest wall disease (n = 19; 8%). At follow-up, measures of all five goals were available in 141 (56%) patients. NIV initiation was adequate for 96 (68%) patients and successful for 12 (9%) patients. In multivariate analysis, a tidal volume ≥ 7.8 ml/kg of ideal body weight was associated with an increased likelihood of adequate NIV initiation (hazard ratio: 5.765 [95% CI:1.824-18.223], p = 0.006]. Improvement in daytime partial arterial carbon dioxide pressure (PaCO ) was not correlated to improvement in HRQL or sleep quality. Severe to very severe NIV-related side effects occurred in 114 (47%) patients and were associated with higher daytime PaCO (6.35 ± 1.08 vs. 5.92 ± 0.79 kPa, p < 0.001).
Conclusion: Successful home NIV initiation is rarely achieved in real life. HRQL and NIV tolerance should be assessed to improve patient-centred outcomes.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/resp.14118 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!