The effect of counting duration on quantitative fecal egg count test performance.

Vet Parasitol

M.H. Gluck Equine Research Center, Department of Veterinary Science, University of Kentucky, 1400 Nicholasville Road, Lexington, KY 40546, USA. Electronic address:

Published: November 2019

Fecal egg counts are the primary diagnostic tools of equine parasitology and use of the McMaster test and its variants in clinical practice is widely recommended. Manual counting is, however, prone to various sources of human error. For example, in real-world situations analysts can be under significant pressure to process high numbers of samples in a limited time. This practice could affect test result quality, but yet no studies have determined whether this is the case. This study's purpose was to assess the effect of shortened counting duration (from either restricting counting time or counting only one grid of a slide) on McMaster test performance, and to compare the results to those of an automated test whose output is not subject to such limitations. Fifteen fecal samples from horses infected with strongylid parasites were divided equally into three groups based on high, medium and low levels of egg content (201-500, 501-1000 and 1001+ eggs/g). Slurries were produced from each sample and 10subsamples of each were counted by both the McMaster and automated methods. McMaster slides were first counted at leisure, and then twice again with counting time being restricted to either one or two min. The effect of reducing sample processing time by counting only one grid of the McMaster slide was also assessed. Counting for one min significantly decreased manual egg counts by 50-60% relative to counts conducted at leisure (p<0.001). While these decreases were somewhat ameliorated by counting for two min, the results were still approximately 10% lower than the at-leisure counts, a difference that was also statistically significant (p<0.001). Furthermore, restricted counting duration also resulted in a significant decrease of approximately one-third in McMaster test precision, as assessed by the coefficients of variation (CoVs) of the 10 replicates of each sample, as did counting just a single grid of the McMaster slide. These differences effectively further improved the observed superior precision of the automated method compared to at-leisure manual McMaster counting, and the automated counts and their precision remained relatively unaffected following multiple analyses of the same processed samples. Taken together, these results indicate that analysists should carefully assess the possible effects on test performance of modifications to standard egg-counting procedures that are designed to account for real-world pressures, in order to achieve an optimal compromise between test accuracy and precision on one hand and practicality on the other.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.vpoa.2019.100020DOI Listing

Publication Analysis

Top Keywords

counting
8
counting duration
8
fecal egg
8
test performance
8
egg counts
8
mcmaster test
8
counting time
8
time counting
8
counting grid
8
test
5

Similar Publications

Background: Digital nerve injuries significantly affect hand function and quality of life, necessitating effective reconstruction strategies. Autologous nerve grafting remains the gold standard due to its superior biocompatibility, despite recent advancements in nerve conduits and allogenic grafts. This study aims to propose a novel zone-based strategy for donor nerve selection to improve outcomes in digital nerve reconstruction.

View Article and Find Full Text PDF

To assess efficacy and safety of dapsone in adult immune thrombocytopenia (ITP), a multicenter randomized controlled trial (RCT) and a real-word study cohort were performed. Participants were adults with primary ITP, transient response to corticosteroids ± intravenous immunoglobulin, and a platelet count ≤ 30x109/L (or ≤ 50x109/L with bleeding). Patients in the RCT were randomized in arm A (prednisone x3weeks+dapsone for 12 months) or arm B (prednisone alone).

View Article and Find Full Text PDF

H*10 neutron dosimetry (unlike gamma dosimetry), requires consideration of neutron energy spectra due to the 20× variation of the weight factor over the thermal-to-fast energy range, as well as the neutron radiation field dose rates ranging from cosmic, ~.01 μSv h-1 levels to commonly encountered ~10-200 μSv h-1 in nuclear laboratories/processing plants, and upwards of 104 Sv h-1 in nuclear reactor environments. This paper discusses the outcome of the comparison of spectrum-weighted neutron dosimetry covering thermal-to-fast energy using the novel H*-TMFD spectroscopy-enabled sensor system in comparison with measurements using state-of-the-art neutron dosimetry systems at SRNS-Rotating Spectrometer (ROSPEC), and non-spectroscopic Eberline ASP2E ("Eberline") and Ludlum 42-49B ("Ludlum") survey instrumentation.

View Article and Find Full Text PDF

Objective: Although dysregulated inflammation has been postulated as a biological mechanism associated with post-acute sequelae of severe acute respiratory coronavirus 2 (SARS-CoV-2) infection (PASC) and shown to be a correlate and an outcome of PASC, it is unclear whether inflammatory markers can prospectively predict PASC risk. We examined the association of leukocyte count and high-sensitivity C-reactive protein (hsCRP) concentrations, measured ~25 years prior to the coronavirus disease 2019 (COVID-19) pandemic, with PASC, PASC severity, and PASC-associated cognitive outcomes at follow-up among postmenopausal women.

Methods: Using biomarker data from blood specimens collected during pre-pandemic enrollment (1993-1998) and data on 1,237 Women's Health Initiative participants who completed a COVID-19 survey between June 2021 and February 2022, we constructed multivariable regression models that controlled for pertinent characteristics.

View Article and Find Full Text PDF

Hydrogen production via water-splitting or ammonia electrolysis using transition metal-based electrodes is one of the most cost-effective approaches. Herein, ca. 1-4% of Pt atoms are stuffed into a wolframite-type NiWO lattice to improve the electrocatalytic efficiency.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!