Mecor: An R package for measurement error correction in linear regression models with a continuous outcome.

Comput Methods Programs Biomed

Department of Clinical Epidemiology, Leiden University Medical Center, Leiden, Netherlands; Department of Biomedical Data Sciences, Leiden University Medical Center, Leiden, Netherlands.

Published: September 2021

Measurement error in a covariate or the outcome of regression models is common, but is often ignored, even though measurement error can lead to substantial bias in the estimated covariate-outcome association. While several texts on measurement error correction methods are available, these methods remain seldomly applied. To improve the use of measurement error correction methodology, we developed mecor, an R package that implements measurement error correction methods for regression models with a continuous outcome. Measurement error correction requires information about the measurement error model and its parameters. This information can be obtained from four types of studies, used to estimate the parameters of the measurement error model: an internal validation study, a replicates study, a calibration study and an external validation study. In the package mecor, regression calibration methods and a maximum likelihood method are implemented to correct for measurement error in a continuous covariate in regression analyses. Additionally, methods of moments methods are implemented to correct for measurement error in the continuous outcome in regression analyses. Variance estimation of the corrected estimators is provided in closed form and using the bootstrap.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cmpb.2021.106238DOI Listing

Publication Analysis

Top Keywords

measurement error
44
error correction
20
regression models
12
continuous outcome
12
measurement
11
error
11
mecor package
8
models continuous
8
outcome measurement
8
outcome regression
8

Similar Publications

The current study investigated the geometry, design and solid angle impacts on full energy peak efficiency (FEPE) of NaI(Tl) detectors for a line source. A line source is fabricated using 99mTc solution filled in a borosilicate glass tube of inner diameter 3 mm, tube wall thickness 2.5 mm and length 12.

View Article and Find Full Text PDF

Discourse on measurement.

Proc Natl Acad Sci U S A

February 2025

Department of Psychology, University of Potsdam, Potsdam 14476, Germany.

Measurement literacy is required for strong scientific reasoning, effective experimental design, conceptual and empirical validation of measurement quantities, and the intelligible interpretation of error in theory construction. This discourse examines how issues in measurement are posed and resolved and addresses potential misunderstandings. Examples drawn from across the sciences are used to show that measurement literacy promotes the goals of scientific discourse and provides the necessary foundation for carving out perspectives and carrying out interventions in science.

View Article and Find Full Text PDF

Analyzing and mitigating the risks of patient harm during operating room to intensive care unit patient handoffs.

Int J Qual Health Care

January 2025

Faculdade de Medicina, Universidade de São Paulo (USP), Av. Dr. Arnaldo, 455 - Sala 4107, São Paulo, São Paulo 01246-903, Brazil.

Patients continue to suffer from preventable harm and uneven quality outcomes. Reliable clinical outcomes depend on the quality of robust administrative systems and reliable support processes. Critically ill patient handoffs from the operating room (OR) to the intensive care unit (ICU) are known to be high-risk events.

View Article and Find Full Text PDF

This scoping review focuses on the evolution of pre-analytical errors (PAEs) in medical laboratories, a critical area with significant implications for patient care, healthcare costs, hospital length of stay, and operational efficiency. The Covidence Review tool was used to formulate the keywords, and then a comprehensive literature search was performed using several databases, importing the search results directly into Covidence (n=379). Title, abstract screening, duplicate removal, and full-text screening were done.

View Article and Find Full Text PDF

Background: A surgical robot with force feedback can guarantee precise and gentle manipulation for endometrial repair, ensuring the effectiveness and safety of the manipulation. However, the design of force sensors for surgical robots is challenging due to the limited anatomical space and the requirement for continuous rotation.

Methods: This paper presents a novel force-sensing surgical instrument for endometrial repair, including an inner scraping instrument and an outer force sensing sheath.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!