Breakage of sliding hip screw after fixation of pertrochanteric hip fracture: A rare complication.

Int J Surg Case Rep

Division of Orthopedic Surgery, Lebanese University, Faculty of Medical Sciences, Beirut, Lebanon.

Published: August 2021

Introduction: The authors report a rare case of lag screw breakage in a patient treated using locking DHS with home-made trochanteric stabilizing plate (TSP) for pertrochanteric hip fracture.

Case Presentation: A 67 year-old female was operated for pertrochanteric hip fracture with incompetent lateral wall using locking DHS with home-made TSP. At seven months postoperative, there was radiographic nonunion with breakage of the sliding lag screw. Patient was consequently scheduled for total hip replacement.

Discussion: Breakage of DHS lag screw has been attributed to multiple-cycle, low-stress fatigue failure associated with nonunion. Predisposing factors are: situation of the medial edge of the barrel at the level of the fracture site prohibiting fracture compression, and mechanical obstacle to the lag screw back sliding into the barrel. In our case, the use of handmade TSP interdicted lag screw back sliding and prevented fracture impaction which was already impaired by the location of the medial edge of the barrel at the fracture level. Additionally our fixation construct was very rigid because of the use of locking screws in the DHS side plate.

Conclusion: When DHS fixation is planned for unstable or potentially unstable trochanteric hip fracture the surgeon should be prepared by making available a TSP from the manufacturer in the operative room rather than improvising intra-operatively with handmade TSP; this augmentation device shouldn't interfere with lag screw back sliding. Furthermore the DHS barrel should ideally not impinge with the fracture site, and the use of locking screws in the DHS plate should be cautious.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8326727PMC
http://dx.doi.org/10.1016/j.ijscr.2021.106226DOI Listing

Publication Analysis

Top Keywords

lag screw
24
pertrochanteric hip
12
hip fracture
12
screw sliding
12
breakage sliding
8
fracture
8
locking dhs
8
dhs home-made
8
medial edge
8
edge barrel
8

Similar Publications

Background: Extra-articular but severely comminuted distal basal fractures of the proximal phalanx (PP) are rarely reported. Therefore, the aim of this study was to achieve proper union and desirable outcomes using low-profile locking plates/screws. We introduced our own surgical approach and reported the clinical/radiographic outcomes via retrospective case series.

View Article and Find Full Text PDF

Higher interfragmentary compression force improves lateral tibial plateau fracture stability using locking plate fixation: experimental and simulation verification.

BMC Musculoskelet Disord

December 2024

Department of Anatomy, Guangdong Provincial Key Laboratory of Digital Medicine and Biomechanics, Guangdong Engineering Research Center for Translation of Medical 3D Printing Application, National Virtual & Reality Experimental Education Center for Medical Morphology, School of Basic Medical Sciences, Southern Medical University, No.1023, South Shatai Road, Baiyun District, Guangzhou, Guangdong, 510515, China.

Background: This study investigated the impact of higher interfragmentary compression force (IFCF) on the stability of locking plate fixation in lateral tibial plateau fractures.

Methods: Biomechanical experiments and finite element analysis (FEA) were employed to compare the performance of the AO cancellous lag screw (AOCLS) and a newly developed combined cancellous lag screw (CCLS).

Results: The results demonstrated that the CCLS provided a higher IFCF without the risk of over-screwing, significantly improving fixation stability.

View Article and Find Full Text PDF

Background: Subtrochanteric proximal femoral fractures are generally treated with cephalomedullary nail fixation. We aimed to compare outcomes of subtrochanteric fracture fixation using a single lag screw (Gamma3 nail, GN) or dual lag screw (INTERTAN nail, IN) device.

Methods: The primary outcome measure was mechanical failure, defined as lag screw cut-out or back-out, nail breakage, or peri-implant fracture.

View Article and Find Full Text PDF

Hypertrophic non-union, after an isolated fibular fracture with intact tibia, is an extremely uncommon complication. The aim of the current study is to present an infrequent case of hypertrophic non-union after an isolated fracture in the proximal diaphysis of fibula which was treated surgically. A 23-year-old male patient presented to our hospital with persistent pain on the lateral aspect of his right leg.

View Article and Find Full Text PDF

A customized dynamic hip screw for valgus osteotomy in femoral neck nonunion with remarkable anatomy: A case report.

Trauma Case Rep

December 2024

Department of Orthopaedic Surgery, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok 10700, Thailand.

We report the treatment of femoral neck nonunion in an adult female who has remarkable femoral neck anatomy. The initial fracture was treated by closed reduction and multiple screws incorporated pin fixation. Eventually, nonunion with implant loosening developed after about 10 following months.

View Article and Find Full Text PDF