Purpose: To compare the organ-dose and effective-dose (E) delivered to the patient during percutaneous vertebroplasty (PVP) of one thoracic or lumbar vertebra performed under CT guidance or using a fixed C-arm.

Methods: Consecutive adult patients undergoing PVP of one vertebra under CT-guidance, with optimized protocol and training of physicians, or using a fixed C-arm were retrospectively included from January 2016 to June 2017. Organ-doses were computed on 16 organs using CT Expo 2.4 software for the CT procedures and PCXMC 2.0 for the fixed C-arm procedures. E was also computed with both software. Dosimetric values per anatomic locations for all procedures were compared using the paired Mann-Whitney-Wilcoxon test.

Results: In total, 73 patients were analysed (27 men and 46 women, mean age 78 ± 10 years) among whom 35 (48%) underwent PVP under CT guidance and 38 (52%) PVP using a fixed C-arm. The median E was 11.31 [6.54; 15.82] mSv for all PVPs performed under CT guidance and 5.58 [3.33; 8.71] mSv for fixed C-arm and the differences was significant (p<0.001). For lumbar PVP, the organ doses of stomach, liver and colon were significantly higher with CT-scan than with the fixed C-arm: 97% (p=0.02); 21% (p=0.099) and 375% (p=0.002), respectively. For thoracic PVP, the lung organ dose was significantly higher with CT-scan than with the fixed C-arm (127%; p<0.001) and the oesophagus organ doses were not significantly different (p = 0.626).

Conclusion: This study showed that the E and the organ dose on directly exposed organs were both higher for PVP performed under CT-guidance than with the fixed C-arm.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejmp.2021.07.002DOI Listing

Publication Analysis

Top Keywords

fixed c-arm
20
performed guidance
12
percutaneous vertebroplasty
8
guidance fixed
8
fixed
6
c-arm
5
retrospective comparison
4
comparison organ
4
organ dose
4
dose effective
4

Similar Publications

A systematic review and meta-analysis of radiation exposure in spinal surgeries: Comparing C-Arm, CT navigation, and O-Arm techniques.

J Med Imaging Radiat Sci

December 2024

Pediatric Orthopaedic Department, Hôpital Robert Debré, Groupe Hospitalier Universitaire AP-HP Nord-Université Paris-Cité, Paris, France; Associate Professor, Center for Orthopedic Trans-Disciplinary Applied, Research (COTAR), Tehran University of Medical Sciences, Tehran, Iran. Electronic address:

Introduction: Advanced imaging techniques, such as C-arm fluoroscopy, O-arm, and CT navigation, are integral to achieving precision in orthopedic surgeries. However, these technologies also expose patients, surgeons, and operating room staff to varying levels of radiation. This systematic review and meta-analysis evaluate the radiation exposure (RE) associated with these imaging modalities and their impact on surgical outcomes.

View Article and Find Full Text PDF

Increasingly, interventional thoracic workflows utilize cone-beam CT (CBCT) to improve navigational and diagnostic yield. Here, we investigate the feasibility of implementing free-breathing 4D respiratory CBCT for motion mitigated imaging in patients unable to perform a breath-hold or without suspending mechanical ventilation during thoracic interventions. Circular 4D respiratory CBCT imaging trajectories were implemented on a clinical robotic CBCT system using additional real-time control hardware.

View Article and Find Full Text PDF

A Rare Case of Transepiphyseal Distal Femur Fracture Dislocation With Delayed Recovery of a Common Peroneal Nerve Injury.

Cureus

July 2024

Orthopaedics and Trauma, Dr. D. Y. Patil Medical College, Hospital and Research Centre, Dr. D. Y. Patil Vidyapeeth, Pune (Deemed to Be University), Pune, IND.

The aim of this study is to bring attention to a unique case and our approach to treatment in this context. We describe a case of an 11-year-old male who presented to us with an injury to his left knee following trauma with pain, swelling, shortening and deformity for one day. An X-ray revealed a transepiphyseal fracture dislocation of the left distal femur (Salter-Harris type 1 injury) and neurovascular examination was conclusive of foot drop which pointed towards injury to common peroneal nerve (CPN).

View Article and Find Full Text PDF

Introduction: Despite recent advances, management of distal tibial fractures is challenging, with high rate of complications. Fibula pro tibia plating technique fixes fibula and tibia together, via laterally placed fibular plate without disturbing the tibial soft tissue sleeve. We contemplated this pilot study to assess effectiveness of fibula pro tibia plating in management of distal tibia fibula fractures.

View Article and Find Full Text PDF

Intertrochanteric femur fracture is a common type of osteoporotic fracture in elderly patients, and postoperative femoral head varus following proximal femoral nail anti-rotation (PFNA) fixation is a crucial factor contributing to the deterioration of clinical outcomes. The cross-angle between the implant and bone might influence fixation stability. Although there is a wide range of adjustment in the direction of anti-rotation blades within the femoral neck, the impact of this direct variation on the risk of femoral head varus and its biomechanical mechanisms remain unexplored.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!