Background: Physical behavior researchers using motion sensors often use acceleration summaries to visualize, clean, and interpret data. Such output is dependent on device specifications (e.g., dynamic range, sampling rate) and/or are proprietary, which invalidate cross-study comparison of findings when using different devices. This limits flexibility in selecting devices to measure physical activity, sedentary behavior, and sleep.

Purpose: Develop an open-source, universal acceleration summary metric that accounts for discrepancies in raw data among research and consumer devices.

Methods: We used signal processing techniques to generate a Monitor-Independent Movement Summary unit (MIMS-unit) optimized to capture normal human motion. Methodological steps included raw signal harmonization to eliminate inter-device variability (e.g., dynamic g-range, sampling rate), bandpass filtering (0.2-5.0 Hz) to eliminate non-human movement, and signal aggregation to reduce data to simplify visualization and summarization. We examined the consistency of MIMS-units using orbital shaker testing on eight accelerometers with varying dynamic range (±2 to ±8 g) and sampling rates (20-100 Hz), and human data (N = 60) from an ActiGraph GT9X.

Results: During shaker testing, MIMS-units yielded lower between-device coefficient of variations than proprietary ActiGraph and ENMO acceleration summaries. Unlike the widely used ActiGraph activity counts, MIMS-units were sensitive in detecting subtle wrist movements during sedentary behaviors.

Conclusions: Open-source MIMS-units may provide a means to summarize high-resolution raw data in a device-independent manner, thereby increasing standardization of data cleaning and analytical procedures to estimate selected attributes of physical behavior across studies.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8301210PMC
http://dx.doi.org/10.1123/jmpb.2018-0068DOI Listing

Publication Analysis

Top Keywords

monitor-independent movement
8
movement summary
8
physical behavior
8
acceleration summaries
8
dynamic range
8
sampling rate
8
raw data
8
shaker testing
8
data
7
open-source monitor-independent
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!