-Butanol or 1-butan- -ol (D9B) is often used as an OH radical tracer in atmospheric chemistry studies to determine OH exposure, a useful universal metric that describes the extent of OH radical oxidation chemistry. Despite its frequent application, there is only one study that reports the rate coefficient of D9B with OH radicals, (295 K), which limits its usefulness as an OH tracer for studying processes at temperatures lower or higher than room temperature. In this study, two complementary experimental techniques were used to measure the rate coefficient of D9B with OH radicals, (), at temperatures between 240 and 750 K and at pressures within 2-760 Torr. A thermally regulated atmospheric simulation chamber was used to determine () in the temperature range of 263-353 K and at atmospheric pressure using the relative rate method. A low-pressure (2-10 Torr) discharge flow tube reactor coupled with a mass spectrometer was used to measure () at temperatures within 240-750 K, using both the absolute and relative rate methods. The agreement between the two experimental aproaches followed in this study was very good, within 6%, in the overlapping temperature range, and (295 ± 3 K) was 3.42 ± 0.26 × 10 cm molecule s, where the quoted error is the overall uncertainty of the measurements. The temperature dependence of the rate coefficient is well described by the modified Arrhenius expression, = (1.57 ± 0.88) × 10 × (/293) × exp(1606 ± 164/) cm molecule s in the range of 240-750 K, where the quoted error represents the 2σ standard deviation of the fit. The results of the current study enable an accurate estimation of OH exposure in atmospheric simulation experiments and expand the applicability of D9B as an OH radical tracer at temperatures other than room temperature.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8296604PMC
http://dx.doi.org/10.1021/acsomega.1c01942DOI Listing

Publication Analysis

Top Keywords

rate coefficient
16
d9b radical
8
radical tracer
8
coefficient d9b
8
d9b radicals
8
room temperature
8
atmospheric simulation
8
temperature range
8
relative rate
8
quoted error
8

Similar Publications

GFR Estimation and Correlation for Oncology Patients by Two Methods, Gates Method and Dual Time Point Plasma Sampling Method.

Indian J Nucl Med

November 2024

Department of Nuclear Medicine and Molecular Imaging, Homi Bhabha Cancer Hospital and Mahamana Pandit Madan Mohan Malaviya Cancer Centre, Tata Memorial Centre, Homi Bhabha National Institute (HBNI), Varanasi, India.

Background: With the increasing number of oncology cases and a parallel surge in chemotherapeutic drugs for treatment, the treating physicians conducts nephrotoxicity evaluation to provide a personalized dosing strategy. Of the various tests available, glomerular filtration rate (GFR) under gamma camera with help of Gates method has gained importance, being a good index of overall kidney functions. In addition to this, there has been an alternate and old method for GFR estimation: plasma sampling.

View Article and Find Full Text PDF

The aim of this ecological study was to examine the correlation between cancer incidence and health behaviors such as smoking, alcohol consumption, and obesity, and investigated whether there were differences in this correlation between metropolitan areas and other regions. Data on health behaviors exposure/prevalence and cancer incidence rates for 227 administrative districts (cities and counties) were obtained. The average exposure proportion measured annually from 2008 to 2011 in the Korea Community Health Survey data and the age-standardized cancer incidence data from 2014 to 2018, obtained through the cancer registry data, were downloaded from the Statistics Korea website.

View Article and Find Full Text PDF

Reliability and Accuracy of the Fitbit Charge 4 Photoplethysmography Heart Rate Sensor in Ecological Conditions: Validation Study.

JMIR Mhealth Uhealth

January 2025

ULR 7369 - URePSSS - Unité de Recherche Pluridisciplinaire Sport Santé Société, Univ. Littoral Côte d'Opale, Univ. Lille, Univ. Artois, 189b, Avenue Maurice Schumann, Centre Universitaire des Darses, Dunkerque, 59375, France, 33 328237357.

Background: Wrist-worn photoplethysmography (PPG) sensors allow for continuous heart rate (HR) measurement without the inconveniences of wearing a chest belt. Although green light PPG technology reduces HR measurement motion artifacts, only a limited number of studies have investigated the reliability and accuracy of wearables in non-laboratory-controlled conditions with actual specific and various physical activity movements.

Objective: The purpose of this study was to (1) assess the reliability and accuracy of the PPG-based HR sensor of the Fitbit Charge 4 (FC4) in ecological conditions and (2) quantify the potential variability caused by the nature of activities.

View Article and Find Full Text PDF

Drums are the core working mechanism of the coal mining machine for coal mining. The structural design level of the drum is crucial for mining efficiency and safety production. Traditional design methods not only have long design cycles and high costs, but also limited design capabilities.

View Article and Find Full Text PDF

Measuring Residents' Competence in Chest Tube Insertion on Thiel-Embalmed Bodies: A Validity Study.

Simul Healthc

December 2024

From the Department of Human Structure and Repair, Faculty of Medicine and Health Sciences, Ghent University, Ghent, Belgium (L.D.M., I.V.H., L.D., W.W.); Department of Thoracic and Vascular Surgery, Ghent University Hospital, Ghent, Belgium (I.V.H., L.D.); Department of Basic and Applied Medical Sciences, Faculty of Medicine and Health Sciences, Ghent University, Ghent, Belgium (P.V.d.V.); Department of Emergency Medicine, Ghent University Hospital, Ghent, Belgium (P.V.d.V.); Department of Gastrointestinal Surgery, Ghent University Hospital, Ghent, Belgium (H.V., W.W.); Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark (L.K.); and Copenhagen Academy for Medical Education and Simulation (CAMES), Copenhagen, Denmark (L.K.).

Introduction: Chest tube insertions (CTIs) have a high complication rate, prompting the training of technical skills in simulated settings. However, assessment tools require validity evidence prior to their implementation. This study aimed to collect validity evidence for assessment of technical skills in CTI on Thiel-embalmed human bodies.

View Article and Find Full Text PDF