Background And Purpose: Hybrid magnetic resonance linear accelerator (MR-Linac) systems represent a novel technology for online adaptive radiotherapy. 3D secondary dose calculation (SDC) of online adapted plans is required to assure patient safety. Currently, no 3D-SDC solution is available for 1.5T MR-Linac systems. Therefore, the aim of this project was to develop and validate a method for online automatic 3D-SDC for adaptive MR-Linac treatments.
Materials And Methods: An accelerator head model was designed for an 1.5T MR-Linac system, neglecting the magnetic field. The use of this model for online 3D-SDC of MR-Linac plans was validated in a three-step process: (1) comparison to measured beam data, (2) investigation of performance and limitations in a planning phantom and (3) clinical validation using n = 100 patient plans from different tumor entities, comparing the developed 3D-SDC with experimental plan QA.
Results: The developed model showed median gamma passing rates compared to MR-Linac base data of 84.7%, 100% and 99.1% for crossplane, inplane and depth-dose-profiles, respectively. Comparison of 3D-SDC and full dose calculation in a planning phantom revealed that with 5 beams gamma passing rates 95% can be achieved for central target locations. With a median calculation time of 1:23 min, 3D-SDC of online adapted clinical MR-Linac plans demonstrated a median gamma passing rate of 98.9% compared to full dose calculation, whereas experimental plan QA reached 99.5%.
Conclusion: Here, we describe the first technical 3D-SDC solution for online adaptive MR-guided radiotherapy. For clinical situations with peripheral targets and a small number of beams additional verification appears necessary. Further improvement may include 3D-SDC with consideration of the magnetic field.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8295847 | PMC |
http://dx.doi.org/10.1016/j.phro.2021.05.002 | DOI Listing |
J Radiol Prot
January 2025
Department of Mechanical Engineering, University of Houston, Houston, 77204, UNITED STATES.
Although the Boundary Representation (BREP) method creates detailed surface phantoms of Chinese women of childbearing age, these phantoms cannot be directly used in Monte Carlo simulations. They must first be converted into voxel phantoms, a process that may diminish some of the inherent advantages of the surface phantoms. Therefore, the aim of this study is to construct a tetrahedral mesh (TM) phantom of Chinese women of childbearing age based on the BREP phantom, incorporating micron-level structural refinements to certain organ tissues while maintaining the original model's structure.
View Article and Find Full Text PDFJ Appl Clin Med Phys
January 2025
Department of Radiation Medicine and Applied Sciences, UC San Diego Health, La Jolla, California, USA.
Purpose: Daily online adaptive radiotherapy (ART) improves dose metrics for gynecological cancer patients, but the on-treatment process is resource-intensive requiring longer appointments and additional time from the entire adaptive team. To optimize resource allocation, we propose a model to identify high-priority patients.
Methods: For 49 retrospective cervical and endometrial cancer patients, we calculated two initial plans: the treated standard-of-care (Initial) and a reduced margin initial plan (Initial) for adapting with the Ethos treatment planning system.
Drug Des Devel Ther
January 2025
Department of Hematology, Jining NO. 1 People's Hospital, Jining, 272000, People's Republic of China.
Purpose: Mitoxantrone (MTX) is largely restricted in clinical usage due to its significant cardiotoxicity. Multiple studies have shown that an imbalance in the gut-heart axis plays an important role in the development of cardiovascular disease (CVD). We aim to explore the possible correlations between gut microbiota (GM) compositions and cardiometabolic (CM) disorder in MTX-triggered cardiotoxicity mice.
View Article and Find Full Text PDFInt J Biomed Imaging
January 2025
Medical Imaging Sciences Department, College of Health Sciences, Gulf Medical University, Ajman, UAE.
The quality of CT images obtained from hepatocellular carcinoma (HCC) patients is complex, affecting diagnostic accuracy, precision, and radiation dose assessment due to increased exposure risks. The study evaluated image quality qualitatively and quantitatively by comparing quality levels with an effective radiation dose to ensure acceptable quality accuracy. This study retrospectively reviewed 100 known HCC patients (Li-RADS-5) who underwent multidetector computed tomography (MDCT) multiphasic scans for follow-up of their health condition between January and October 2023.
View Article and Find Full Text PDFCureus
December 2024
Gastroenterology, St Mark's Hospital and Academic Institute, London, GBR.
The therapeutic failure of infliximab therapy remains a challenge in patients with inflammatory bowel disease (IBD), and dose optimization is often required. Accelerated or intensified regimes showed value in treating patients in the acute setting with high CRP or low albumin levels, which are suggested by recent guidelines; however, evidence is weak. Therapeutic drug monitoring (TDM), with anti-tumor necrosis factor-alpha (TNF-α) trough levels and antibodies, showed value during maintenance therapy, but not in induction and can guide clinical decisions in patients that might be undertreated with the standard dosing regimen.