Photon noise and constant-volume operators.

J Opt Soc Am A

Department of Cognitive Sciences, University of California, Irvine 92717.

Published: December 1987

In an earlier paper [J. Opt. Soc. Am. A 2, 1769 (1985)] a class of nonlinear image processing operators was introduced in which each photoreceptor creates a nonnegative point-spread function whose center height is proportional to its quantum catch and whose volume is constant, so that the local spatial-summation area varies inversely with the local quantum catch. These constant-volume (CV) operators are designed to maximize spatial resolution in the presence of photon noise. In the previous paper it was shown that when CV operators are applied to deterministic images, they produce a surprising range of effects that are reminiscent of human vision, including Mach bands and Weber's-law behavior. In this paper the consequences of applying CV operators to images containing Poisson noise are analyzed. It is shown that a fixed-parameter CV operator can duplicate the global qualitative properties of spatial vision for retinal illuminances ranging from absolute threshold to 1000 Td. Although there are fundamental obstacles to modeling the exact quantitative properties of human spatial vision by CV operators, these operators seem likely to be useful in machine vision.

Download full-text PDF

Source
http://dx.doi.org/10.1364/josaa.4.002418DOI Listing

Publication Analysis

Top Keywords

photon noise
8
constant-volume operators
8
quantum catch
8
spatial vision
8
operators
7
noise constant-volume
4
operators earlier
4
earlier paper
4
paper opt
4
opt soc
4

Similar Publications

Dual opposing quadrature-PT symmetry.

iScience

January 2025

Department of Electrical and Computering Engineering, Binghamton University, Binghamton, NY 13902, USA.

Our recent research on type-I quadrature parity-time (PT) symmetry, utilizing an open twin-beam system, not only enables observing genuine quantum photonic PT symmetry amid phase-sensitive amplification (PSA) and loss in the presence of Langevin noise but also reveals an additional classical-to-quantum (C2Q) transition in noise fluctuations. In contrast to the previous setup, our exploration of an alternative system assuming no loss involves a type-II PSA-only scheme. This scheme facilitates dual opposing quadrature-PT symmetry, offering a comprehensive and complementary comprehension of C2Q transitions and PT-enhanced quantum sensing with optimal performance in the symmetry unbroken region.

View Article and Find Full Text PDF

Significance: Maximal safe resection of brain tumors can be performed by neurosurgeons through the use of accurate and practical guidance tools that provide real-time information during surgery. Current established adjuvant intraoperative technologies include neuronavigation guidance, intraoperative imaging (MRI and ultrasound), and 5-ALA for fluorescence-guided surgery.

Aim: We have developed intraoperative Raman spectroscopy as a real-time decision support system for neurosurgical guidance in brain tumors.

View Article and Find Full Text PDF

Evaluation of charge summing correction in CdTe-based photon-counting detectors for breast CT: performance metrics and image quality.

J Med Imaging (Bellingham)

January 2025

U.S. Food and Drug Administration, Office of Science and Engineering Labs, Division of Imaging, Diagnostics, and Software Reliability, Silver Spring, Maryland, United States.

Purpose: We evaluate the impact of charge summing correction on a cadmium telluride (CdTe)-based photon-counting detector in breast computed tomography (CT).

Approach: We employ a custom-built laboratory benchtop system using the X-THOR FX30 0.75-mm CdTe detector (Varex Imaging, Salt Lake City, Utah, United States) with a pixel pitch of 0.

View Article and Find Full Text PDF

Ratiometric lanthanide coordination polymers (Ln-CPs) are advanced materials that combine the unique optical properties of lanthanide ions (e.g., Eu, Tb, Ce) with the structural flexibility and tunability of coordination polymers.

View Article and Find Full Text PDF

Narrow Linewidth All-Optical Microwave Oscillator Based on Torsional Radial Acoustic Modes of Single-Mode Fiber.

Micromachines (Basel)

January 2025

Key Laboratory of Instrumentation Science and Dynamic Measurement Ministry of Education, North University of China, Taiyuan 030051, China.

A Hz level narrow linewidth all-optical microwave oscillator based on the torsional radial acoustic modes (TR) of a single-mode fiber (SMF) is proposed and validated. The all-optical microwave oscillator consists of a 20 km SMF main ring cavity and a 5 km SMF sub ring cavity. The main ring cavity provides forward stimulated Brillouin scattering gain and utilizes a nonlinear polarization rotation effect to achieve TR mode locking.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!