We report on results of experimental flow measurements inside a bone scaffold model, subjected to a uniform incoming flow (applied perfusion). Understanding the flow behavior inside a tissue engineered scaffold is essential for mechanistic studies of mechanobiology, particularly flow-sensitive bone cells. Nearly all existing studies that quantify interstitial flow inside engineered bone scaffolds have been based on numerical results, in part due to the difficulties associated with quantitative measurements and visualization of flow inside large, opaque bone or bone mimics. Thus, an experimental platform to complement and validate in silico studies is needed. Therefore, we developed a flow visualization method using Phase-Contrast Magnetic Resonance Imaging (PC-MRI) to measure flow velocities within a 3D-printed microCT-based rendering of a bone scaffold. We designed and built a non-magnetic recirculating water tunnel to apply uniform perfusion to the 3D-printed model and we measured flow distribution within the scaffold and compared these experimental results with CFD results. Both magnitude and distribution of flow velocities observed at different slices of the scaffold were in quantitative agreement numerically and experimentally. This experimental approach can be used to both validate numerical studies and provide insight into the flow behavior inside tissue-engineered scaffolds for a range of applications, including fundamental mechanobiology of healthy cells, and in the context of diseases, such as cancer.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jbiomech.2021.110625DOI Listing

Publication Analysis

Top Keywords

flow inside
12
bone scaffold
12
flow
11
inside bone
8
flow behavior
8
behavior inside
8
flow velocities
8
bone
7
scaffold
6
inside
5

Similar Publications

Quantitative investigation of a 3D bubble trapper in a high shear stress microfluidic chip using computational fluid dynamics and L*A*B* color space.

Biomed Microdevices

January 2025

Chakri Naruebodindra Medical Institute, Faculty of Medicine Ramathibodi Hospital, Mahidol University, 111 Suwannabhumi Canal Rd, Bang Pla, Bang Phli District, Samut Prakan, 10540, Thailand.

Microfluidic chips often face challenges related to the formation and accumulation of air bubbles, which can hinder their performance. This study investigated a bubble trapping mechanism integrated into microfluidic chip to address this issue. Microfluidic chip design includes a high shear stress section of fluid flow that can generate up to 2.

View Article and Find Full Text PDF

Industrial Investigations of S355 Steel-Grade Homogenization in a 100-Tonne Ladle Furnace.

Materials (Basel)

January 2025

Faculty of Production Engineering and Materials Technology, Częstochowa University of Technology, al. Armii Krajowej 19, 42-201 Częstochowa, Poland.

The paper presents the results of industrial research and numerical simulations of the chemical homogenization of liquid steel. The research object was a ladle furnace with a working capacity of the ladle of 100 t at the steel plant of Huta Częstochowa, currently Liberty Częstochowa Sp. z o.

View Article and Find Full Text PDF

The cavitation water jet cleaning and coating removal technique represents an innovative sustainable method for cleaning and removing coatings, with the nozzle serving as a crucial component of this technology. Developing an artificially submerged nozzle with a reliable structure and excellent cavitation performance is essential for enhancing cavitation water jets' cleaning and coating removal efficacy in an atmosphere environment (non-submerged state). This study is based on the shear flow cavitation mechanism of an angular nozzle, the resonance principle of an organ pipe, and the jet pump principle.

View Article and Find Full Text PDF

X-ray spectroscopies are uniquely poised to describe the geometric and electronic structure of metalloenzyme active sites under a wide variety of sample conditions. UV/Vis (ultraviolet/visible) spectroscopy is a similarly well-established technique that can identify and quantify catalytic intermediates. The work described here reports the first simultaneous collection of full in situ UV/Vis and high-energy resolution fluorescence detected x-ray absorption spectra.

View Article and Find Full Text PDF

Nematic liquid crystal flow driven by time-varying active surface anchoring.

Soft Matter

January 2025

Faculty of Mathematics and Physics, University of Ljubljana, Jadranska 19, 1000 Ljubljana, Slovenia.

We demonstrate the generation of diverse material flow regimes in nematic liquid cells as driven by time-variable active surface anchoring, including no-net flow, oscillatory flow, steady flow, and pulsating flow. Specifically, we numerically simulate a passive nematic fluid inside a cell bounded with two flat solid boundaries at which the time-dependent anchoring is applied with the dynamically variable surface anchoring easy axis. We show that different flow regimes emerge as the result of different anchoring driving directions ( co-rotating or counter-rotating) and relative phase of anchoring driving.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!