The aim of the study was to compare the response of calvarial and femoral osteoblasts cultured in a 3D hydrogel environment to cyclic compressive mechanical loading. Human foetal femoral and calvarial osteoblasts were encapsulated in a semi-synthetic thiol-modified hyaluronan gelatin polyethylene glycol diacrylate (PEGDA) cross-linked HyStemC hydrogel. Constructs were subjected to a cyclic compressive strain of 33.4 kPa force every second for 5 s every hour for 6 h per day using FlexCell BioPress culture plates and compared to non-compressed constructs. Cell viability, mineralisation, and morphological changes were observed over 21 days. BMP2, ALP, COL1A1, COL2A1, and OCN gene expression levels were quantified. Encapsulated osteoblast numbers increased and formed hydroxyapatite over a 21-day period. Cell viability decreased under a cyclical strain when compared to cells under no strain. Femoral osteoblasts under strain expressed increased levels of BMP2 (53.9-fold) and COL1A1 (5.1-fold) mRNA compared to no strain constructs. Surprisingly, no BMP2 mRNA was detected in calvarial osteoblasts. Osteoblasts derived from endochondral (femoral) and intra-membranous (calvarial) processes behaved differently in 3D-constructs. We therefore recommend that site-specific osteoblasts be used for future bone engineering and bone replacement materials and further research undertaken to elucidate how site-specific osteoblasts respond to cyclic compressive loads.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/eos.12818 | DOI Listing |
Bioact Mater
April 2025
University of Coimbra, CEMMPRE, Department of Mechanical Engineering, 3030-788, Coimbra, Portugal.
Polymeric coronary stents, like the ABSORB™, are commonly used to treat atherosclerosis due to their bioresorbable and cell-compatible polymer structure. However, they face challenges such as high strut thickness, high elastic recoil, and lack of radiopacity. This study aims to address these limitations by modifying degradable stents produced by additive manufacturing with poly(lactic acid) (PLA) and poly(ε-caprolactone) (PCL) with degradable metallic coatings, specifically zinc (Zn) and magnesium (Mg), deposited via radiofrequency (rf) magnetron sputtering.
View Article and Find Full Text PDFComput Biol Med
December 2024
Department of Mathematics, Capital University of Science and Technology, Islamabad, 44000, Pakistan.
The dynamic behavior of articular cartilage (a soft porous biological tissue) with strain-dependent nonlinear permeability under cyclic compressive loading and magnetic field is investigated computationally. The compressive force is applied on top surface of the cylindrical plug of the tissue by means of a porous filter. The study of mechanical and deformational behavior of soft porous tissues such as articular cartilage under dynamic compressive loading and magnetic field is useful in understanding the underlying mechano-biological process that may lead to the development of a treatment and recovery protocol in a diseased state.
View Article and Find Full Text PDFInt J Biol Macromol
December 2024
State Key Laboratory of Chemistry and Utilization of Carbon Based Energy Resources, College of Chemistry, Xinjiang University, Urumqi 830017, Xinjiang, PR China. Electronic address:
Stretchable conductive hydrogels have attracted great attention in flexible electronics. Nevertheless, conductive hydrogels would suffer from an inevitable damage during use, significantly reducing the reliability and limiting the practicability. Herein, stretchable and self-healing conductive hydrogels are designed form carboxymethyl cellulose (CMC), polyacrylic acid (PAA), and Fe, which are applied for monitoring human motions and electrophysiological signals.
View Article and Find Full Text PDFSensors (Basel)
December 2024
School of Civil Engineering, Zhengzhou University, Zhengzhou 450001, China.
The stress status of a soil pressure cell placed in soil is very different from its stress state in a uniform fluid medium. The use of the calibration coefficient provided by the soil pressure cell manufacturer will produce a large error. In order to improve the measurement accuracy of the interface-type earth pressure cell placed in soil, this paper focuses on a single-membrane resistive earth pressure cell installed on the surface of a structure, analyzing the influence of loading and unloading cycles, the thickness and particle size of the sand filling, and the depth of the earth pressure cell inserted in the structure on the calibration curve and matching error, which were analyzed through calibration tests.
View Article and Find Full Text PDFSensors (Basel)
November 2024
Department of Civil, Construction, and Environmental Engineering, Iowa State University, Ames, IA 50011, USA.
This paper explores the development of 3D-printed self-sensing Ultra-High Performance Concrete (UHPC) by incorporating graphite (G) powder, milled carbon microfiber (MCMF), and chopped carbon microfiber (CCMF) as additives into the UHPC matrix to enhance piezoresistive properties while maintaining workability for 3D printing. Percolation curves were established to identify optimal filler inclusion levels, and a series of compressive tests, including quasi-static cyclic, dynamic cyclic, and monotonic compressive loading, were conducted to evaluate the piezoresistive and mechanical performance of 29 different mix designs. It was found that incorporating G powder improved the conductivity of the UHPC but decreased compressive strength for both mold-cast and 3D-printed specimens.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!