Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
A better understanding of the spatial sensitivity of the human circadian system to photic stimulation can provide practical solutions for optimized circadian light exposures. Two psychophysical experiments, involving 25 adult participants in Experiment 1 (mean age = 34.0 years [SD 15.5]; 13 females) and 15 adult participants in Experiment 2 (mean age = 43.0 years [SD 12.6]; 12 females), were designed to investigate whether varying only the spatial distribution of luminous stimuli in the environment while maintaining a constant spectrally weighted irradiance at the eye could influence nocturnal melatonin suppression. Two spatial distributions were employed, one where the luminous stimulus was presented On-axis (along the line of sight) and one where two luminous stimuli were both presented Off-axis (laterally displaced at center by 14°). Two narrowband LED light sources, blue ( = 451 nm) for first experiment and green ( = 522 nm) for second experiment, were used in both the On-axis and the Off-axis spatial distributions. The blue luminous stimulus targeting the fovea and parafovea (On-axis) was about three times more effective for suppressing melatonin than the photometrically and spectrally matched stimulus targeting the more peripheral retina (Off-axis). The green luminous stimulus targeting the fovea and parafovea (On-axis) was about two times more effective for suppressing melatonin than the photometrically and spectrally matched stimulus targeting the more peripheral retina (Off-axis).
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8278206 | PMC |
http://dx.doi.org/10.1016/j.nbscr.2021.100071 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!