Alternatives to nasopharyngeal sampling are needed to increase capacity for SARS-CoV-2 testing. Among 275 participants, we piloted the collection of nasal mid-turbinate swabs amenable to self-testing, including polyester flocked swabs as well as 3D-printed plastic lattice swabs, placed into viral transport media or an RNA stabilization agent. Flocked nasal swabs identified 104/121 individuals who were PCR-positive for SARS-CoV-2 by nasopharyngeal sampling (sensitivity 87%, 95% CI 79-92%), missing those with low viral load (<10 viral copies/mL). 3D-printed nasal swabs showed similar sensitivity. When nasal swabs were placed directly into RNA preservative, the mean 1.4 log decrease in viral copies/uL compared to nasopharyngeal samples was reduced to <1 log, even when samples were left at room temperature for up to 7 days. We also evaluated pooling strategies that involved pooling specimens in the lab versus pooling swabs at the point of collection, finding both successfully detected samples with >10 viral copies/mL.