A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Stress-Strain and Stress-Relaxation Behaviors of Solution-Coated Layers Composed of Block Copolymers Mixed with Tackifiers. | LitMetric

The relationship between the mechanical properties and the structure of block copolymers mixed with tackifiers whose relative solubility to the respective components of block copolymers differs was examined. Coated layers were prepared by solution coating using a block copolymer composed of polystyrene (PS) and polyisoprene (PI), which forms spherical microdomains of PS in the PI matrix, mixed with three types of tackifiers: aliphatic (C5) resin, aliphatic-aromatic (C5-C9) resin, and rosin ester (RE) resin. Furthermore, the correlation between the changes in the nanostructure and mechanical properties including the stress-relaxation behaviors was clarified by two-dimensional small-angle X-ray scattering measurement. The amount of the PI-bridge conformation in the case of C5 resin is the lowest, resulting in the lowest stress. On the contrary, the largest amount of RE resin was solubilized in the PS phase so that it can be considered that pulling out of the PS chains took place easily. We were able to explain the stress-relaxation behavior by fitting with the three-component exponent functions. The triple exponential decay functions indicate the hierarchy of the structures that are the origins of the ″fast mode″ relating to the local relaxation due to the rotation of the repeating unit of polymer chains; the ″intermediate mode″ of the disentanglement of the mid-PI chains; and the ″slow mode″ relating to, in this particular case, pulling out of the PS chains from the PS sphere.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8280650PMC
http://dx.doi.org/10.1021/acsomega.1c01367DOI Listing

Publication Analysis

Top Keywords

block copolymers
12
stress-relaxation behaviors
8
copolymers mixed
8
mixed tackifiers
8
mechanical properties
8
pulling chains
8
mode″ relating
8
resin
5
stress-strain stress-relaxation
4
behaviors solution-coated
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!